MétaCan
Menu
Back to cohort
Record W3132687263

Performance and limitations of high granularity single photon processing X-ray imaging detectors

2005· article· en· W3132687263 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

fundA Canadian funder is recorded on the work.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenuereposiTUm (TU Wien) · 2005
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsnot available
FundersEuropean Synchrotron Radiation FacilityCERNMcGill University
KeywordsGranularityDetectorComputer sciencePhotonPhysicsOptics
DOInot available

Abstract

fetched live from OpenAlex

Progress in CMOS technology and in fine pitch bump bonding has made possible the development of single photon counting detectors for X-ray imaging with pixel pitches on the order of 50 µm giving a spatial resolution which is comparable to conventional CCD and flat panel detectors. This thesis studies the interaction of X-ray photons in the energy range of 5 keV to 70 keV with various sensor materials as well as the response of the Medipix2 readout system to both monochromatic and wide spectrum X-ray sources. Single photon processing offers the potential for spectroscopic imaging. However, this thesis demonstrates using simulations and measurements that the charge deposition and collection within the semiconductor sensor impose fundamental limits on the achievable energy resolution. In particular the discussion of charge during collection in the sensor and the generation of fluorescence photons in heavier sensor materials contribute to the appearance of a low energy tail on the detected spectrum of an incoming beam. On the other hand, with the application of appropriate flat-field correction maps, the systemem operates to the Poisson limit. As the electronic noise in a pixel channel is around 100e rms and typical energy thresholds are over 1000e excellent quality images of low contrast objects have been produced using both intense and weak X-ray sources. The Modulation Transfer Function has been measured to be 9.1 lp/mm corresponding to the pixel aperture function. The Detective Quantum Efficiency is only limited by the sensor material used and does not change as a function of dose, highlighting the enormous potential for low dose imaging with such a system. The Medipix2 system has an upper threshold in each pixel too which allows an energy window of down to 1.4 keV FWHM to be selected and scanned in the range of 4 keV to 100 keV. First images using the energy threshold window demonstrate the potential of the technique to extract a spectral image when only a broad band source of X-rays is available.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.480
Threshold uncertainty score0.660

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.198
Teacher spread0.188 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it