MétaCan
Menu
Back to cohort
Record W3133003147 · doi:10.1093/ejcts/ezab018

Five-year outcomes of patients supported with HeartMate 3: a single-centre experience

2021· article· en· W3133003147 on OpenAlexaff
Jan D. Schmitto, Silvia Mariani, Tong Li, Guenes Dogan, Jasmin S. Hanke, Christoph Bara, Yuriy Pya, Daniel Zimpfer, Thomas Krabatsch, Jens Garbade, Vivek Rao, Michiel Morshuis, Friedhelm Beyersdorf, Silvana Marasco, Ivan Netuka, Johann Bauersachs, Axel Haverich

Bibliographic record

VenueEuropean Journal of Cardio-Thoracic Surgery · 2021
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsToronto General Hospital
FundersAbbott Fund
KeywordsMedicineVentricular assist deviceAdverse effectHeart failureQuality of life (healthcare)Clinical endpointClinical trialProspective cohort studyCohortDestination therapySurgeryHaemolysisInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVES: The HeartMate 3 left ventricular assist device was first implanted in 2014 and received the Conformité Européenne mark in 2015. Since then, several trials demonstrated its high haemocompatibility associated with good survival and low adverse events rates. Herein, we report our institutional experience with patients supported with HeartMate 3 for 5 years. METHODS: This prospective cohort study included patients receiving a HeartMate 3 implantation in 2014 as part of the HeartMate 3 Conformité Européenne Mark clinical trial. Patients had follow-up visits every 3 months while on left ventricular assist device support, and all patients completed the 5-year follow-up. The primary end point was survival at 5 years. Secondary end points included adverse events, health status and quality of life. RESULTS: Eight patients (men: 75%) aged 59 years (min-max: 52-66 years) were enrolled. At 5 years, survival was 100%. Patients remained on support for a median time of 1825 days (min-max: 101-1825 days); 2 patients successfully received cardiac transplants. No right heart failure, haemolysis, pump thrombosis, pump malfunction or neurological events occurred in any patients. A driveline infection was observed in 6 patients (0.25 events/patient-year). Compared to baseline, a significant improvement in quality of life and in New York Heart Association functional class was noted after the implant and for the whole follow-up time. A slight decline in kidney function and in the 6-min walk test results occurred after 3 years. CONCLUSIONS: This study reports the longest single-centre follow-up of the HeartMate 3, showing excellent haemocompatibility over time with high survival and low complication rates at 5 years.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.041
Threshold uncertainty score0.785

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.230
Teacher spread0.207 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2021
Admission routes1
Has abstractyes

Explore more