MétaCan
Menu
Back to cohort
Record W3133034402 · doi:10.1016/j.jvs.2021.01.047

Clinical trial outcomes and thoracic aortic morphometry after one year with the Valiant Navion stent graft system

2021· article· en· W3133034402 on OpenAlexaff
Fabio Verzini, Nimesh D. Desai, Frank R. Arko, Jean M. Panneton, Fabien Thaveau, François Dagenais, Jia Guo, Ali Azizzadeh

Bibliographic record

VenueJournal of Vascular Surgery · 2021
Typearticle
Languageen
FieldMedicine
TopicAortic Disease and Treatment Approaches
Canadian institutionsUniversité du Québec
FundersMedtronic
KeywordsMedicineStentNoticeRecallClinical trialSurgeryRadiologyInternal medicine

Abstract

fetched live from OpenAlex

AUTHORS' NOTE: On February 17, 2021, Medtronic Incorporated issued a global voluntary recall of the Valiant Navion Thoracic Stent Graft System (the device under study in the Valiant Evo Global Clinical Program that is the subject of this publication), and instructed physicians to immediately cease use of the Valiant Navion system and return any unused product. Medtronic initiated the recall in response to three clinical trial subjects recently observed with stent fractures, two of whom have confirmed type IIIb endoleaks. The data collection, analysis, and manuscript submission occurred before the notice of this recall, and, specifically, the 100 procedures reviewed for this series were free of events at 1 year related to the reason for this device recall. The authors of this article and the manufacturer were unaware of the recently detected adverse events at the time of the preparation of the manuscript, and the 1-year trial results, and imaging-based analyses described are unchanged. Management of thoracic aortic aneurysms continues to be a challenging problem and outcomes are dependent on patient anatomy. The present publication focuses on the importance of achieving proximal and distal seals and the consideration of the temporal changes of the aortic morphology as a part of the TEVAR planning process. The authors believe there is still scientific merit in disclosing this information, despite the current nonavailability of the Valiant Navion system. OBJECTIVE: The Valiant Navion stent graft system (Medtronic Inc, Santa Rosa, Calif) is a third-generation device with improved conformability. We have reported the 1-year clinical trial outcomes, with a focus on an imaging-based analysis of the aortic morphology. We assessed the effects of graft implantation on the native anatomy and the effects of the 1-year changes in thoracic aorta morphology on the original seal zones of the stent graft. METHODS: A total of 100 subjects were enrolled in a prospective single-arm clinical trial investigating the Valiant Navion stent graft system. An independent core laboratory (Syntactx, New York, NY) assessed the anatomic characteristics and performance outcomes. RESULTS: Through 1 year of follow-up, the freedom from all-cause mortality, aneurysm-related mortality, and secondary procedures was 89.8%, 97.0%, and 94.8% respectively. Of the 100 patients, 5 had undergone a total of six secondary procedures, and 9 patients had developed an endoleak (type Ia and Ib in 1, type Ia in 1, type Ib in 3, and type II in 4 patients) within the first year. After 1 year, 2 of 76 patients (2.6%) had had an increase in their maximum aneurysm diameter of ≥5 mm, 62 (81.6%) had had stable sacs, and 12 (15.8%) had experienced sac shrinkage. Although no deployment failures had occurred, 36 of the 100 proximal (36%) and 31 of the 100 distal (31%) attachment zones were considered short according to our definitions. The stent graft had conformed to the native anatomy at implantation, because the preprocedural thoracic aorta tortuosity (1.45 ± 0.02) had not significantly changed at 1 month after implantation (1.46 ± 0.02). Despite a natural increase in thoracic tortuosity after 1 year (1.49 ± 0.02), wall apposition had been maintained over time, as evidenced by the low endoleak rates. Aortic elongation and dilation had occurred at the proximal end of the graft by an average of 1.2 mm and 1.6 mm, respectively. Aortic remodeling was more pronounced at the distal end, with an average increase of 4.2 mm in length and 2.8 mm in diameter. CONCLUSIONS: The included patients had had positive 1-year outcomes with high freedom from mortality, endoleak development, and secondary procedures. Aortic elongation and dilation were more prevalent at the distal end, emphasizing the importance of distal attachment zone consideration as part of preoperative planning. Because aortic remodeling can be expected to continue over time, additional follow-up and imaging analysis in the trial will be necessary to assess the aortic morphology and its effects on stent graft performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.301

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.325
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Vascular SurgerySame topicAortic Disease and Treatment ApproachesFrench-language works237,207