Automated detection and quantification of reverse triggering effort under mechanical ventilation

2021· article· en· W3133276869 on OpenAlexaff
Tài Pham, Jaume Montanyà, Irene Telías, Thomas Piraino, Rudys Magrans, Rémi Coudroy, L. Felipe Damiani, Ricard Mellado Artigas, Matías Madorno, Lluís Blanch, Laurent Brochard, César Santis, Tommaso Mauri, Elena Spinelli, Giacomo Grasselli, Savino Spadaro, Carlo Alberto Volta, Francesco Mojoli, Dimitris Georgopoulos, Εumorfia Kondili, Stella Soundoulounaki, Tobias Becher, Norbert Weiler, Dirk Schaedler, Oriol Roca, Manel M. Santafé, Jordi Mancebo, Leo Heunks, Heder de Vries, Chang-Wen Chen, Zhou Jian-xin, Guangqiang Chen, Nuttapol Rittayamai, Norberto Tiribelli, Sebastián Fredes, C. Ferrando Ortolá, François Beloncle, Alain Mercat, Jean-Michel Arnal, JL Diehl, Alexandre Demoule, Martin Dres, Sébastien Jochmans, Jonathan Chelly, Nicolas Terzi, Claude Guérin, Elias Baedorf Kassis, Jeremy R. Beitler, Davide Chiumello, Erica Ferrari Luca Bolgiaghi, Vito Fanelli, Jean-Emmanuel Alphonsine, Arnaud W. Thille, Laurent Papazian

Bibliographic record

VenueCritical Care · 2021
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsSinai Health SystemUniversity Health NetworkMcMaster UniversityUniversity of TorontoSt. Michael's Hospital
Fundersnot available
KeywordsMedicineAirwayMechanical ventilationReproducibilityCardiologyAnesthesiaInternal medicine

Abstract

fetched live from OpenAlex

Abstract Background Reverse triggering (RT) is a dyssynchrony defined by a respiratory muscle contraction following a passive mechanical insufflation. It is potentially harmful for the lung and the diaphragm, but its detection is challenging. Magnitude of effort generated by RT is currently unknown. Our objective was to validate supervised methods for automatic detection of RT using only airway pressure (Paw) and flow. A secondary objective was to describe the magnitude of the efforts generated during RT. Methods We developed algorithms for detection of RT using Paw and flow waveforms. Experts having Paw, flow and esophageal pressure (Pes) assessed automatic detection accuracy by comparison against visual assessment. Muscular pressure (Pmus) was measured from Pes during RT, triggered breaths and ineffective efforts. Results Tracings from 20 hypoxemic patients were used (mean age 65 ± 12 years, 65% male, ICU survival 75%). RT was present in 24% of the breaths ranging from 0 (patients paralyzed or in pressure support ventilation) to 93.3%. Automatic detection accuracy was 95.5%: sensitivity 83.1%, specificity 99.4%, positive predictive value 97.6%, negative predictive value 95.0% and kappa index of 0.87. Pmus of RT ranged from 1.3 to 36.8 cmH 2 0, with a median of 8.7 cmH 2 0. RT with breath stacking had the highest levels of Pmus, and RTs with no breath stacking were of similar magnitude than pressure support breaths. Conclusion An automated detection tool using airway pressure and flow can diagnose reverse triggering with excellent accuracy. RT generates a median Pmus of 9 cmH 2 O with important variability between and within patients. Trial registration BEARDS, NCT03447288.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score0.239

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.341
Teacher spread0.299 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations66
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueCritical CareSame topicRespiratory Support and MechanismsFrench-language works237,207