An Ultra-Miniaturized Antenna With Ultra-Wide Bandwidth Characteristics for Medical Implant Systems

2021· article· en· W3133883328 on OpenAlexaff
Muhammad Yousaf, Ismail Ben Mabrouk, Muhammad Zada, Adeel Akram, Yasar Amin, Mourad Nedil, Hyoungsuk Yoo

Bibliographic record

VenueIEEE Access · 2021
Typearticle
Languageen
FieldEngineering
TopicWireless Body Area Networks
Canadian institutionsUniversité du Québec en Abitibi-Témiscamingue
FundersDepartment of Education and KnowledgeMinistry of Education, Science and TechnologyNational Research Foundation of KoreaNational Research Foundation
KeywordsBandwidth (computing)NotationComputer scienceTopology (electrical circuits)MathematicsCombinatoricsTelecommunicationsArithmetic

Abstract

fetched live from OpenAlex

In this study, an ultra–miniaturized implantable antenna based system with ultra-wideband characteristics in the industrial, scientific, and medical band (i.e., 2.4–2.48 GHz) is proposed for biomedical applications. A biocompatible and flexible liquid crystalline polymer material, Rogers ULTRALAM (tan$\delta =0.0025$and$\varepsilon _{r} =2.9$), is employed as both the substrate and superstrate. The proposed antenna with a compact size ($7\times 7\times0.2$mm3) and a wide bandwidth (1533 MHz), was primarily designed for overcoming the detuning challenges that may occur owing to the electronic circuitry and irregularity as well as inhomogeneity of the human tissue environment. The miniaturization of this antenna was achieved by introducing a shorting pin and open-ended cuts in the ground plane, as well as in the radiating patch. The proposed antenna also yielded a higher gain and lower specific absorption rate (SAR). Through the link budget analysis, it was observed that 1 Mbps of data could be easily transmitted over a distance of 15 m. The simulated and in vitro measured results confirmed that compared to the recently reported antenna systems, our proposed ultra-wideband antenna based system could work more efficiently in the complex environment of the human body, thus establishing itself as an attractive candidate for biomedical applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.253
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations61
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueIEEE AccessSame topicWireless Body Area NetworksFrench-language works237,207