MétaCan
Menu
Back to cohort
Record W3133918036 · doi:10.1088/1741-2552/ac1d5b

Towards adaptive deep brain stimulation: clinical and technical notes on a novel commercial device for chronic brain sensing

2021· review· en· W3133918036 on OpenAlexfundno aff
Yohann Thenaisie, Chiara Palmisano, Andrea Canessa, Bart J. Keulen, Philipp Capetian, Mayté Castro Jiménez, Julien F. Bally, Elena Manferlotti, Laura Beccaria, Rodi Zutt, Grégoire Courtine, Jocelyne Bloch, Niels A. van der Gaag, C.F.E. Hoffmann, Eduardo Martin Moraud, Ioannis U. Isaias, Maria Fiorella Contarino

Bibliographic record

VenueJournal of Neural Engineering · 2021
Typereview
Languageen
FieldMedicine
TopicNeurological disorders and treatments
Canadian institutionsnot available
FundersParkinson SchweizEuropean CommissionHorizon 2020 Framework ProgrammeDeutsche ForschungsgemeinschaftYork UniversityFondazione Grigioni per il Morbo di ParkinsonCentre Hospitalier Universitaire VaudoisSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungSchool of Medicine, New York UniversityNational Science Foundation
KeywordsDeep brain stimulationBrain stimulationComputer scienceNeuroscienceStimulationBrain implantMedicineArtificial intelligencePsychologyInternal medicine

Abstract

fetched live from OpenAlex

Abstract Objective . Technical advances in deep brain stimulation (DBS) are crucial to improve therapeutic efficacy and battery life. We report the potentialities and pitfalls of one of the first commercially available devices capable of recording brain local field potentials (LFPs) from the implanted DBS leads, chronically and during stimulation. The aim was to provide clinicians with well-grounded tips on how to maximize the capabilities of this novel device, both in everyday practice and for research purposes. Approach . We collected clinical and neurophysiological data of the first 20 patients (14 with Parkinson’s disease (PD), five with dystonia, one with chronic pain) that received the Percept™ PC in our centres. We also performed tests in a saline bath to validate the recordings quality. Main results . The Percept PC reliably recorded the LFP of the implanted site, wirelessly and in real time. We recorded the most promising clinically useful biomarkers for PD and dystonia (beta and theta oscillations) with and without stimulation. Furthermore, we provide an open-source code to facilitate export and analysis of data. Critical aspects of the system are presently related to contact selection, artefact detection, data loss, and synchronization with other devices. Significance . New technologies will soon allow closed-loop neuromodulation therapies, capable of adapting stimulation based on real-time symptom-specific and task-dependent input signals. However, technical aspects need to be considered to ensure reliable recordings. The critical use by a growing number of DBS experts will alert new users about the currently observed shortcomings and inform on how to overcome them.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.146
GPT teacher head0.412
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations134
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Neural EngineeringSame topicNeurological disorders and treatmentsFrench-language works237,207