MétaCan
Menu
Back to cohort
Record W3138443838 · doi:10.1097/pcc.0000000000002714

Variability in the Hemodynamic Response to Fluid Bolus in Pediatric Septic Shock

2021· article· en· W3138443838 on OpenAlexaff
Suchitra Ranjit, Rajeswari Natraj, Niranjan Kissoon, Ravi R. Thiagarajan, R. Balasubramaniam, Manuel Ignacio Monge García

Bibliographic record

VenuePediatric Critical Care Medicine · 2021
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsBC Children's Hospital
Fundersnot available
KeywordsMedicineSeptic shockMean arterial pressureCardiac indexHemodynamicsBlood pressureCentral venous pressureAnesthesiaBolus (digestion)Interquartile rangeCardiologyCardiac outputVascular resistanceInternal medicineHeart rateSepsis

Abstract

fetched live from OpenAlex

OBJECTIVES: Fluid boluses are commonly administered to improve the cardiac output and tissue oxygen delivery in pediatric septic shock. The objective of this study is to evaluate the effect of an early fluid bolus administered to children with septic shock on the cardiac index and mean arterial pressure, as well as on the hemodynamic response and its relationship with outcome. DESIGN, SETTING, PATIENTS, AND INTERVENTIONS: We prospectively collected hemodynamic data from children with septic shock presenting to the emergency department or the PICU who received a fluid bolus (10 mL/kg of Ringers Lactate over 30 min). A clinically significant response in cardiac index-responder and mean arterial pressure-responder was both defined as an increase of greater than or equal to 10% 10 minutes after fluid bolus. MEASUREMENTS AND MAIN RESULTS: Forty-two children with septic shock, 1 month to 16 years old, median Pediatric Risk of Mortality-III of 13 (interquartile range, 9-19), of whom 66% were hypotensive and received fluid bolus within the first hour of shock recognition. Cardiac index- and mean arterial pressure-responsiveness rates were 31% and 38%, respectively. We failed to identify any association between cardiac index and mean arterial pressure changes (r = 0.203; p = 0.196). Cardiac function was similar in mean arterial pressure- and cardiac index-responders and nonresponders. Mean arterial pressure-responders increased systolic, diastolic, and perfusion pressures (mean arterial pressure - central venous pressure) after fluid bolus due to higher indexed systemic vascular resistance and arterial elastance index. Mean arterial pressure-nonresponders required greater vasoactive-inotrope support and had higher mortality. CONCLUSIONS: The hemodynamic response to fluid bolus in pediatric septic shock was variable and unpredictable. We failed to find a relationship between mean arterial pressure and cardiac index changes. The adverse effects of fluid bolus extended beyond fluid overload and, in some cases, was associated with reduced mean arterial pressure, perfusion pressures and higher vasoactive support. Mean arterial pressure-nonresponders had increased mortality. The response to the initial fluid bolus may be helpful to understand each patient's individualized physiologic response and guide continued hemodynamic management.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.016
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.034
Threshold uncertainty score0.992

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.016
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.336
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuePediatric Critical Care MedicineSame topicHemodynamic Monitoring and TherapyFrench-language works237,207