MétaCan
Menu
Back to cohort
Record W3146074201 · doi:10.1109/tmtt.2021.3065560

Biotelemetry and Wireless Powering of Biomedical Implants Using a Rectifier Integrated Self-Diplexing Implantable Antenna

2021· article· en· W3146074201 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueIEEE Transactions on Microwave Theory and Techniques · 2021
Typearticle
Languageen
FieldEngineering
TopicWireless Power Transfer Systems
Canadian institutionsUniversité du Québec en Abitibi-Témiscamingue
FundersDepartment of Education and KnowledgeMinistry of Education, Science and TechnologyNational Research Foundation of KoreaNational Research Foundation
KeywordsRectifier (neural networks)BiotelemetryElectrical engineeringWireless power transferAntenna (radio)TransmitterMaximum power transfer theoremPower (physics)WirelessRectennaComputer scienceTelemetryPhysicsEngineeringElectromagnetic coilTelecommunicationsVoltageRectificationChannel (broadcasting)

Abstract

fetched live from OpenAlex

This article proposes an efficient and complete wireless power transfer (WPT) system (WPTS) for multipurpose biomedical implants. The WPTS is composed of a self-diplexing implantable antenna, efficient rectifier, and WPT transmitter (WPT Tx). The proposed system is capable of simultaneously transmitting recorded data and recharging the batteries of the devices (so as to elongate the implant life). The WPT Tx occupies dimensions of 50 ×50 ×1.6 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> and is optimized to effectively transfer power at 1470 MHz to a 55-mm deep implantable device. An efficient and compact ( 3.4 ×6.7 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) rectifier is used at 1470 MHz to convert the harvested RF power into a useful direct current (dc) power. The proposed rectifier circuit exhibits a high conversion efficiency of 50% even at an input power of -14 dBm and maximum efficiency of 76.1% at 2 dBm. The proposed self-diplexing implantable antenna occupies small dimensions (9.4 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ) and operates at 915 and 1470 MHz by exciting ports 1 and 2, respectively. The biotelemetry operation is performed using a 915 MHz band (port 1), and the rectifier circuit is connected to port 2 (1470 MHz) to perform wireless powering. The simulated results are validated by examining the individual elements (WPT Tx, rectifier, and self-diplexing antenna) and overall WPTS in a saline solution and minced pork. The results prove that the proposed scheme is suitable for biotelemetry and wireless powering of biomedical implants.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.479
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.230
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it