MétaCan
Menu
Back to cohort
Record W3149913363 · doi:10.33137/jns.v2i1.34645

Smartphone-based Identification of Critical Levels of Glycated Hemoglobin A1c using Transdermal Optical Imaging

2021· article· en· W3149913363 on OpenAlexaffvenue
Hudda Salih, Si Wu, Evgueni Kabakov, Kang Lee, Weihong Zhou

Bibliographic record

VenueUTSC s Journal of Natural Sciences · 2021
Typearticle
Languageen
FieldMedicine
TopicRetinal Imaging and Analysis
Canadian institutionsThe Scarborough HospitalUniversity of Toronto
Fundersnot available
KeywordsGlycated hemoglobinDiabetes mellitusMedicineGlycemicDiabetes managementConfusion matrixArtificial intelligenceMachine learningType 2 diabetesComputer scienceEndocrinology

Abstract

fetched live from OpenAlex

Abstract: Worldwide, the prevalence of diabetes has continued to increase rapidly. This gives rise to concerns regarding appropriate diabetes management to ensure optimal glycemic control. Untreated or uncontrolled diabetes can lead to a host of complications, such as cardiovascular diseases, an increased likelihood of morbidity and mortality (Deshpande, Harris-Hayes, & Schootman, 2008). A challenging problem which arises in diabetes management is the limitations of current blood glucose monitoring techniques. Electronic medical devices can potentially overcome the persistent problems in the healthcare industry. Thus, for this study, it was of interest to investigate whether advanced machine learning methods and Anura, a smartphone-based transdermal optical imaging technology (TOI) that assess health markers, can be a viable solution for diabetes management. Objectives: To examine the validity of TOI and a novel machine algorithm for diabetes prediction (i.e diabetes and non-diabetes). We compared the diabetes classification from TOI’s obtained glycated hemoglobin A1c (HbA1c) concentrations against data obtained from FDA approved blood immunoassay. Methods: In the present study, we used a kitchen sink random forest machine algorithm for diabetes prediction. The data set was obtained from 513 participants recruited during their annual physical examination at the Health Management Center of The Affiliated Hospital of Hangzhou Normal University, China. This included participant’s TOI and blood immunoassay determined HbA1c concentrations. To validate the model, pristine testing was done on 400 pristine participants pseudo randomly selected during 20 trials of training/testing. Results: The confusion matrix found TOI to have a classification accuracy of 66%, and the ROC curve of the RF classifier found TOI to have a ROC AUC of 0.69. Conclusions: The present study provides evidence for the potential use of the TOI technology, Anura, for contactless, non-invasive, and inexpensive assessments of diabetes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.089
Threshold uncertainty score0.286

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.364
Teacher spread0.328 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueUTSC s Journal of Natural SciencesSame topicRetinal Imaging and AnalysisFrench-language works237,207