MétaCan
Menu
Back to cohort
Record W3150609538 · doi:10.1109/jtehm.2021.3069353

Development of a Smart Hallway for Marker-Less Human Foot Tracking and Stride Analysis

2021· article· en· W3150609538 on OpenAlexafffund
Vinod Gutta, Pascal Fallavollita, Natalie Baddour, Edward D. Lemaire

Bibliographic record

VenueIEEE Journal of Translational Engineering in Health and Medicine · 2021
Typearticle
Languageen
FieldHealth Professions
TopicBalance, Gait, and Falls Prevention
Canadian institutionsOttawa HospitalUniversity of Ottawa
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Ottawa
KeywordsFoot (prosody)STRIDEComputer scienceTracking (education)Computer visionArtificial intelligenceSmartwatchPhysical medicine and rehabilitationWearable computerPsychologyMedicineArtComputer securityEmbedded system

Abstract

fetched live from OpenAlex

OBJECTIVE: In this research, a marker-less 'smart hallway' is proposed where stride parameters are computed as a person walks through an institutional hallway. Stride analysis is a viable tool for identifying mobility changes, classifying abnormal gait, estimating fall risk, monitoring progression of rehabilitation programs, and indicating progression of nervous system related disorders. METHODS: Smart hallway was build using multiple Intel RealSense D415 depth cameras. A novel algorithm was developed to track a human foot using combined point cloud data obtained from the smart hallway. A method was implemented to separate the left and right leg point cloud data, then find the average foot dimensions. Foot tracking was achieved by fitting a box with average foot dimensions to the foot, with the box's base on the foot's bottom plane. A smart hallway with this novel foot tracking algorithm was tested with 22 able-bodied volunteers by comparing marker-less system stride parameters with Vicon motion analysis output. RESULTS: With smart hallway frame rate at approximately 60fps, temporal stride parameter absolute mean differences were less than 30ms. Random noise around the foot's point cloud was observed, especially during foot strike phases. This caused errors in medial-lateral axis dependent parameters such as step width and foot angle. Anterior-posterior dependent (stride length, step length) absolute mean differences were less than 25mm. CONCLUSION: This novel marker-less smart hallway approach delivered promising results for stride analysis with small errors for temporal stride parameters, anterior-posterior stride parameters, and reasonable errors for medial-lateral spatial parameters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0020.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0040.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.381
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Journal of Translational Engineering in Health and MedicineSame topicBalance, Gait, and Falls PreventionFrench-language works237,207