MétaCan
Menu
Back to cohort
Record W3150914811

COMPARISON OF SHORT-TERM RESULT BETWEEN HIGH-FLEX AND CONVENTIONAL POSTERIOR-STABILIZED PROSTHESIS IN TOTAL KNEE ARTHROPLASTY

2010· article· en· W3150914811 on OpenAlexaboutno aff
HU Peixin

Bibliographic record

VenueChinese Journal of Reparative and Reconstructive Surgery · 2010
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineProsthesisOsteoarthritisWOMACRheumatoid arthritisRange of motionSurgeryArthroplastyBody mass indexArthritisImplantInternal medicine
DOInot available

Abstract

fetched live from OpenAlex

Objective To compare the short-term result between the high-flex(HF) and conventional posterior-stabilized(PS) prosthesis in total knee arthroplasty(TKA).Methods From April 2005 to October 2007,23 cases(27 knees) underwent TKA by HF prosthesis(HF group),and 35 cases(41 knees) underwent TKA by PS prosthesis(PS group).In HF group,there were 2 males(3 knees) and 21 females(24 knees) aged(64.3±5.6) years,including 20 cases(23 knees) of osteoarthritis and 3 cases(4 knees) of rheumatoid arthritis;body mass index(BMI) was 27.3±3.9;the course of disease was(5.3±5.6) years;the Hospital for Special Surgery Scoring System(HSS) score was 58.4±7.9;the Western Ontario and McMaster universities osteoarthritis index(WOMAC) score was 49.4±6.9;the maximum knee flex degree was(107.6±8.3)°;and the range of knee motion was(103.5±7.7)°.In PS group,there were 3 males(3 knees) and 32 females(38 knees) aged(65.1±5.9) years,including 33 cases(39 knees) of osteoarthritis and 2 cases(2 knees) of rheumatoid arthritis;BMI was 27.1±4.1;the course of disease was(5.1±4.9) years;HSS score was 60.1±10.4;WOMAC score was 47.9±7.2;the maximum knee flex degree was(108.4±9.7)°;and the range of knee motion was(105.9±11.4)°.There were no signif icant differences in general data between two groups(P0.05).Results All incisions achieved healing by first intention.No complication of ankylosis,blood vessel and nerve injuries,and prosthesis loosening occurred.All patients were followed up for 24-54 months(average 32.8 months).There were no significant differences in the HSS score,WOMAC score,the maximum knee flex degrees,and the range of knee motion at 3,12,and 24 months after operation between two groups(P0.05),but there were significant differences between pre-and post-operation(P0.05).Anterior knee pain occurred in 1 case of HF group and 4 cases of PS group after 24 months,the incidence rates were 3.70% in HF group and 9.76% in PS group,showing significant difference(P0.05).The X-ray films showed that no lucent zone around prosthesis and no patella baja were observed,and the force line was excellent.Conclusion There is no significant difference in the range of knee motion and clinical scores between the HF prosthesis and the PS prosthesis,but the former's incidence rate of anterior knee pain is lower.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.318
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueChinese Journal of Reparative and Reconstructive SurgerySame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207