Insulin delivery devices for diabetes mellitus from open-loop to closed-loop
Bibliographic record
Abstract
Insulin therapy is one of the most widely used methods for antidiabetic treatment. In contrast with manually controlled open-loop insulin delivery devices, closed-loop devices are continuously and automatically operated to mimic the natural insulin production process of the pancreas. Insulin pen and pumps are conventional open-loop devices that deliver insulin via subcutaneous injections. Insulin inhaler and tablets are novel devices that enable non-invasive insulin administration. The discomfort and risk of hypoglycemia associated with open-loop administrations facilitated the investigation of glucose-responsive closed-loop devices. Smart insulin pumps with a continuous glucose monitoring (CGM) is able to sense the real-time glucose levels and pause insulin infusion when necessary. Nonelectronic nanotechnology-enabled devices, such as microneedle array patches and hydrogel-containing catheters, demonstrate great value in the future of potential diabetes treatment.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.004 | 0.002 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".