Evaluation of Diagnostic Imaging Capacity and the Role for Point-of-Care Ultrasound (POCUS) within the Zanzibar Health System

2021· article· en· W3157494913 on OpenAlexvenueno aff
Abiola Fasina, Anthony J. Dean, Nova L. Panebianco, Frances S. Shofer, Omar Ali, Mwajuma Yahya, Salim Ismail, Patricia C. Henwood

Bibliographic record

VenuePOCUS Journal · 2021
Typearticle
Languageen
FieldMedicine
TopicUltrasound in Clinical Applications
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineUltrasoundDemographicsDiagnostic ultrasoundHealth careSpecialtyMedical physicsMedical imagingModalitiesPoint of care ultrasoundFamily medicineRadiology

Abstract

fetched live from OpenAlex

Background: The Zanzibar Ministry of Health identified access to ultrasound (US) as a system priority due to limited diagnostic imaging capacity and consequent impact on patient care and requested a needs assessment in this regard. As a result, the objective of this study was to assess diagnostic imaging capacity focusing on ultrasound in Zanzibar, including health care providers’ (HCPs) current training, use, and barriers to implementation. Methods: A previously published ultrasound needs assessment survey was modified and administered on-site at the eight public hospitals in Zanzibar among a convenience sample of HCPs. Demographics, perceived US needs, current training and practice, and availability of specialty support were assessed. HCPs also completed focused personal interviews (FPIs) to explore experience with training, interests, and barriers to ultrasound. On-site diagnostic imaging modalities were assessed. Results: There were nine ultrasound machines present at six of the eight public hospitals assessed. All had x-ray, but only one had a CT scanner and a radiologist. There was no MRI capacity at the hospitals assessed at the time of the study. Survey data among 40 participants revealed that prior experience with POCUS was limited with only 10% reporting any prior ultrasound training or experience. The majority of those surveyed (72%), indicated a ‘high’ interest in learning ultrasound. Of those reporting interest in POCUS applications, obstetrics was the most often cited (70%). Lack of ultrasound machines (40%) and educators (28%) were identified as the greatest barriers. Conclusion: HCPs in Zanzibar have limited access to diagnostic imaging, including ultrasound, and expressed a high level of interest in learning point-of-care ultrasound. A shortage of machines and educators are the main barriers to widespread use. Obstetrics is the application for which ultrasound is currently most used and is the application HCPs are most interested in learning. Equipment and educational support for a POCUS program could improve care by increasing access to diagnostic imaging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.015
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.227
Threshold uncertainty score0.993

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.015
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.349
Teacher spread0.311 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuePOCUS JournalSame topicUltrasound in Clinical ApplicationsFrench-language works237,207