MétaCan
Menu
Back to cohort
Record W3159928448 · doi:10.3390/s21092953

Custom-Fitted In- and Around-the-Ear Sensors for Unobtrusive and On-the-Go EEG Acquisitions: Development and Validation

2021· article· en· W3159928448 on OpenAlexafffund
Olivier Valentin, Guilhem Viallet, Aidin Delnavaz, Gabrielle Crétot-Richert, Mikaël Ducharme, Hami Monsarat-Chanon, Jérémie Voix

Bibliographic record

VenueSensors · 2021
Typearticle
Languageen
FieldNeuroscience
TopicEEG and Brain-Computer Interfaces
Canadian institutionsÉcole de Technologie SupérieureMcGill UniversityCentre for Interdisciplinary Research in Music Media and Technology
FundersMitacs
KeywordsElectroencephalographyWearable computerEar canalComputer scienceLatency (audio)SiliconeAcousticsBiomedical engineeringEngineeringMaterials scienceEmbedded systemTelecommunicationsNeurosciencePsychologyPhysics

Abstract

fetched live from OpenAlex

OBJECTIVES: This paper aims to validate the performance and physical design of a wearable, unobtrusive ear-centered electroencephalography (EEG) device, dubbed "EARtrodes", using early and late auditory evoked responses. Results would also offer a proof-of-concept for the device to be used as a concealed brain-computer interface (BCI). DESIGN: The device is composed of a custom-fitted earpiece and an ergonomic behind-the-ear piece with embedded electrodes made of a soft and flexible combination of silicone rubber and carbon fibers. The location of the conductive silicone electrodes inside the ear canal and the optimal geometry of the behind-the-ear piece were obtained through morphological and geometrical analysis of the human ear canal and the region around-the-ear. An entirely conductive generic earpiece was also developed to assess the potential of a universal, more affordable solution. RESULTS: Early latency results illustrate the conductive silicone electrodes' capability to record quality EEG signals, comparable to those obtained with traditional gold-plated electrodes. Additionally, late latency results demonstrate EARtrodes' capacity to reliably detect decision-making processes from the ear. CONCLUSIONS: EEG results validate the performance of EARtrodes as a circum-aural and intra-aural EEG recording system adapted for a wide range of applications in audiology, neuroscience, clinical research, and as an unobtrusive BCI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.216
Threshold uncertainty score0.395

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.274
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueSensorsSame topicEEG and Brain-Computer InterfacesFrench-language works237,207