MétaCan
Menu
Back to cohort
Record W3161970434 · doi:10.1016/j.imu.2021.100588

IoT based wearable device to monitor the signs of quarantined remote patients of COVID-19

2021· article· en· W3161970434 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueInformatics in Medicine Unlocked · 2021
Typearticle
Languageen
FieldMedicine
TopicCOVID-19 diagnosis using AI
Canadian institutionsHumber Polytechnic
Fundersnot available
KeywordsWearable computerComputer scienceAndroid (operating system)Cloud computingGlobal Positioning SystemMobile deviceWearable technologyEmbedded systemApplication layerReal-time computingWorld Wide WebOperating system

Abstract

fetched live from OpenAlex

Monitoring and managing potential infected patients of COVID-19 is still a great challenge for the latest technologies. In this work, IoT based wearable monitoring device is designed to measure various vital signs related to COVID-19. Moreover, the system automatically alerts the concerned medical authorities about any violations of quarantine for potentially infected patients by monitoring their real time GPS data. The wearable sensor placed on the body is connected to edge node in IoT cloud where the data is processed and analyzed to define the state of health condition. The proposed system is implemented with three layered functionalities as wearable IoT sensor layer, cloud layer with Application Peripheral Interface (API) and Android web layer for mobile phones. Each layer has individual functionality, first the data is measured from IoT sensor layer to define the health symptoms. The next layer is used to store the information in the cloud database for preventive measures, alerts, and immediate actions. The Android mobile application layer is responsible for providing notifications and alerts for the potentially infected patient family respondents. The integrated system has both API and mobile application synchronized with each other for predicting and alarming the situation. The design serves as an essential platform that defines the measured readings of COVID-19 symptoms for monitoring, management, and analysis. Furthermore, the work disseminates how digital remote platform as wearable device can be used as a monitoring device to track the health and recovery of a COVID-19 patient.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.013
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.194
Threshold uncertainty score0.995

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.013
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.357
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it