Development and ex-vivo assessment of a novel patient specific guide and instrumentation system for minimally invasive total shoulder arthroplasty

2021· article· en· W3162351359 on OpenAlexaff
Joshua W. Giles, Cyrus Brodén, Christine Tempelaere, Roger Emery, Ferdinando Rodriguez y Baena

Bibliographic record

VenuePLoS ONE · 2021
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsUniversity of Victoria
FundersLeverhulme TrustWellcome TrustWellcome
KeywordsArthroplastyMedicineNeurovascular bundleCadaveric spasmScapulaShouldersInvasive surgerySurgeryBiomedical engineering

Abstract

fetched live from OpenAlex

OBJECTIVE: To develop and assess a novel guidance technique and instrumentation system for minimally invasive short-stemmed total shoulder arthroplasty that will help to reduce the complications associated with traditional open replacement such as poor muscle healing and neurovascular injury. We have answered key questions about the developed system including (1) can novel patient-specific guides be accurately registered and used within a minimally invasive environment?; (2) can accuracy similar to traditional techniques be achieved? METHODS: A novel intra-articular patient-specific guide was developed for use with a new minimally invasive posterior surgical approach that guides bone preparation without requiring muscle resection or joint dislocation. Additionally, a novel set of instruments were developed to enable bone preparation within the minimally invasive environment. The full procedure was evaluated in six cadaveric shoulders, using digitizations to assess accuracy of each step. RESULTS: Patient-specific guide registration accuracy in 3D translation was 2.2±1.2mm (RMSE±1 SD; p = 0.007) for the humeral component and 2.7±0.7mm (p<0.001) for the scapula component. Final implantation accuracy was 2.9±3.0mm (p = 0.066) in translation and 5.7-6.8±2.2-4.0° (0.001<p<0.009) across the humerus implants' three rotations. Similarly, the glenoid component's implantation accuracy was 3.0±1.7mm (p = 0.008) in translation and 2.3-4.3±2.2-4.4° (0.008<p<0.09) in rotation. CONCLUSION: This system achieves minimally invasive shoulder replacement with accuracy similar to traditional open techniques while avoiding common causes of complications. SIGNIFICANCE: This novel technique could lead to a paradigm shift in shoulder arthroplasty for patients with moderate arthritis, which could significantly improve rehabilitation and functional outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.064
GPT teacher head0.295
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONE→Same topicShoulder Injury and Treatment→French-language works237,207→