MétaCan
Menu
Back to cohort
Record W3163555915 · doi:10.1186/s13018-021-02465-8

Short-term clinical and radiological results of two different design metaphyseal fitting femoral stems in total hip arthroplasty: a prospective, randomized trial

2021· article· en· W3163555915 on OpenAlexaboutno aff
Irini Tatani, Κωνσταντίνα Σώλου, Andreas Panagopoulos, John Lakoumentas, Antonios Kouzelis, Panagiotis Megas

Bibliographic record

VenueJournal of Orthopaedic Surgery and Research · 2021
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineOrthopedic surgeryRadiological weaponRandomized controlled trialArthroplastyTotal hip arthroplastySurgeryHip arthroplasty

Abstract

fetched live from OpenAlex

BACKGROUND: There is great design variability on short femoral stems available on the market. This study aims to evaluate the short-term clinical and radiological results of two different design short femoral stems, both classified as shortened tapered stems. METHODS: From March 2016 to March 2018, a prospective, randomized, parallel-group design study was conducted to compare functional and radiological outcomes of 45 patients underwent THA using the Tri-Lock Bone Preservation Stem and 45 patients underwent THA with the Minima S stem at a minimum 2 years of follow-up. Patients were assessed clinically and radiographically prior to surgery as well as at 3, 6, 12, and 24 months postoperatively. Primary outcomes were the change in health-related quality of life assessed with Western Ontario and McMaster Universities Osteoarthritis Index and 36-Item Short Form Health Survey and also the incidence of all hip-related complications. Secondary aims included hip function evaluated with the Harris hip score, rates of patient satisfaction, and the outcomes of a detailed radiological analysis. RESULTS: There were no significant differences between the 2 study groups in terms of patient-reported outcomes measurements, satisfaction scores, and complication rates at any of the measurement times. In both groups, stable fixation and radiographic osseointegration were achieved. However, analysis of the calcar region showed that 57.8% and 28.9% of patients had grade 1 or 2 stress shielding, in Tri-Lock and Minima S implantation group, respectively (p=0.015). Regarding coronal alignment, stems were placed in slight varus, valgus, and neutral position in 51.1%, 13.3%, and 35.6% of patients, respectively, in Tri-Lock BPS group. The Minima S stem was implanted at slight varus and valgus in 60% and 40% of patients, respectively, and neither stem in the exact neutral position. CONCLUSIONS: Both different design short femoral stems demonstrated excellent clinical performance at short-term follow up. Nevertheless, concerns were raised regarding the incidence of stress shielding phenomenon and mild discrepancies in coronal stem alignment during implantation. The clinical impact of these observations should be further evaluated through larger cohorts and longer follow-up. TRIAL REGISTRATION: ISRCTN registry, ISRCTN10096716 . Registered on May 8, 2018-Retrospectively registered.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.022
metaresearch head score (Gemma)0.009
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.086
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0220.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.153
GPT teacher head0.405
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Orthopaedic Surgery and ResearchSame topicOrthopaedic implants and arthroplastyFrench-language works237,207