MétaCan
Menu
Back to cohort
Record W3164192340 · doi:10.1002/acm2.13265

Four‐dimensional dose calculations for dynamic tumour tracking with a gimbal‐mounted linear accelerator

2021· article· en· W3164192340 on OpenAlexaff
Emilie E. Carpentier, Ronan McDermott, Emma Dunne, Marie‐Laure Camborde, Alanah Bergman, Tania Karan, Mitchell C. C. Liu, Roy M. K., Ante Mestrovic

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2021
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer AgencySpinal Cord Injury BCUniversity of British Columbia
Fundersnot available
KeywordsNuclear medicineDosimetryRotation (mathematics)MedicineWeightingLinear particle acceleratorRadiation treatment planningBreathingBeam (structure)MathematicsRadiation therapyPhysicsRadiologyOptics

Abstract

fetched live from OpenAlex

Abstract Purpose In this study we present a novel method for re‐calculating a treatment plan on different respiratory phases by accurately modeling the panning and tilting beam motion during DTT (the “rotation method”). This method is used to re‐calculate the dose distribution of a plan on multiple breathing phases to accurately assess the dosimetry. Methods sIMRT plans were optimized on a breath hold computed tomography (CT) image taken at exhale (BH exhale ) for 10 previous liver stereotactic ablative radiotherapy patients. Our method was used to re‐calculate the plan on the inhale (0%) and exhale (50%) phases of the four‐dimensional CT (4DCT) image set. The dose distributions were deformed to the BH exhale CT and summed together with proper weighting calculated from the patient’s breathing trace. Subsequently, the plan was re‐calculated on all ten phases using our method and the dose distributions were deformed to the BH exhale CT and accumulated together. The maximum dose for certain organs at risk (OARs) was compared between calculating on two phases and all ten phases. Results In total, 26 OARs were examined from 10 patients. When the dose was calculated on the inhale and exhale phases six OARs exceeded their dose limit, and when all 10 phases were used five OARs exceeded their limit. Conclusion Dynamic tumor tracking plans optimized for a single respiratory phase leave an OAR vulnerable to exceeding its dose constraint during other respiratory phases. The rotation method accurately models the beam’s geometry. Using deformable image registration to accumulate dose from all 10 breathing phases provides the most accurate results, however it is a time consuming procedure. Accumulating the dose from two extreme breathing phases (exhale and inhale) and weighting them properly provides accurate results while requiring less time. This approach should be used to confirm the safety of a DTT treatment plan prior to delivery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.840
Threshold uncertainty score0.700

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.384
Teacher spread0.349 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207