MétaCan
Menu
Back to cohort
Record W3165080655 · doi:10.31234/osf.io/t3gdz

When is it good to use wristband devices to measure HRV?: Introducing a new method for evaluating the quality of data from photophlethysmography-based HRV devices

2019· preprint· en· W3165080655 on OpenAlexaff
William S. Ryan, James H. Conigrave, Geetanjali Basarkod, Joseph Ciarrochi, Baljinder K. Sahdra

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsPhotoplethysmogramHeart rate variabilityArtifact (error)Supine positionComputer scienceMedicineHeart rateArtificial intelligenceWirelessInternal medicineTelecommunicationsBlood pressure

Abstract

fetched live from OpenAlex

Objective: Recent technological advances have led to the proliferation of ambulatory devices for non-invasively assessing cardiac activity. While these devices have exciting implications for conducting research outside the laboratory, it is critical that this increased mobility does not compromise data quality. As a test case, we assess the efficacy of Empatica’s E4, a high-end wristband device designed to assess Heart Rate Variability (HRV) through the use of photoplethysmography. Approach: We compare the E4 to traditional, wired electrocardiogram measures across a variety of conditions, including seated, supine, and standing baselines, as well as typing and grip strength tasks. Most importantly, we introduce and demonstrate the efficacy of a new method for determining the amount of error in HRV estimates derived from the E4 and a technique for adjusting error tolerance. Main Results: Results indicate that the E4 is severely compromised by motion artifact, resulting in a high percentage of missing data across all conditions except seated and supine baselines. Employing error adjustment yielded more robust results, but at the cost of significantly reducing sample size where motion artifact was present. Significance: These results call into question the wristband’s efficacy as an HRV measurement tool in most in-vivo conditions. We recommend that researchers interested in using photoplethysmography-based HRV devices use caution and evaluate the data quality using methods for error detection and tolerance, such as the one presented here.Keywords: heart rate variability, ambulatory photoplethysmography, electrocardiogram.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.022
metaresearch head score (Gemma)0.075
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.022
Threshold uncertainty score0.115

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0220.075
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0030.003
Open science0.0010.002
Research integrity0.0040.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.318
GPT teacher head0.470
Teacher spread0.152 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2019
Admission routes1
Has abstractyes

Explore more

Same topicHeart Rate Variability and Autonomic ControlFrench-language works237,207