Clinical outcomes after implantation of a sutureless aortic bioprosthesis with concomitant mitral valve surgery: the SURE-AVR registry
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Early treatment of aortic valve stenosis is recommended in eligible symptomatic patients with severe aortic valve stenosis who would otherwise have a poor prognosis. The sutureless aortic valve bioprosthesis offers an alternative to standard aortic valve replacement with a sutured valve, but limited data are available in patients who have undergone multiple valve procedures involving the new, sutureless technology. We sought to investigate outcomes in high operative risk patients with previous or concomitant valve surgery who were implanted with a sutureless valve. METHODS: SURE-AVR is an ongoing, prospective, multinational registry of patients undergoing aortic valve replacement. In-hospital and post-discharge outcomes up to 5 years were collected. RESULTS: The study population comprised 78 patients (mean ± SD: age 73.6 ± 7.6 years, logistic EuroSCORE 18.0 ± 17.5) enrolled at 13 sites who presented for concomitant or previous mitral valve repair (n = 45) or replacement (n = 33), with or without additional concomitant procedures, and were implanted with a sutureless valve. Mean ± SD overall aortic cross-clamp time was 109 ± 41 min and cardiopulmonary bypass time was 152 ± 49 min. Mean ± SD aortic pressure gradients decreased from 37.6 ± 17.7 mmHg preoperatively to 13.0 ± 5.7 mmHg at hospital discharge, and peak aortic pressure gradient from 61.5 ± 28.7 to 23.4 ± 10.6 mmHg. Early events included 1 death, 1 transient ischaemic attack, and 1 bleed (all 1.3%); a permanent pacemaker implantation was required in 6 patients (7.7%), and 2 reoperations (not valve related) (2.6%) took place. Over a median follow-up of 55.5 months (Q1 13.4, Q3 68.6), 12 patients died (6 cardiovascular and 6 non-cardiovascular, both 2.1% per patient-year). Five-year survival was 81.3%. Late paravalvular leak occurred in 2 patients (0.7% per patient-year) and permanent pacemaker implantation was required in 3 patients (0.1% per patient-year). There was no apparent rise in mean or peak aortic pressure gradient over the study. CONCLUSIONS: These results suggest that the sutureless implant is a technically feasible procedure during mitral surgery and is associated with good clinical outcomes.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.011 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it