MétaCan
Menu
Back to cohort
Record W3165503764 · doi:10.1088/1361-6579/ac05d5

The effectiveness of continuous respiratory rate monitoring in predicting hypoxic and pyrexic events: a retrospective cohort study

2021· article· en· W3165503764 on OpenAlexaff
Thomas McCartan, Amy P Worrall, Ruán Ó Conluain, Fátimah Alaya, Christopher Mulvey, Elaine MacHale, Vincent Brennan, Lorna Lombard, Joanne Walsh, Myles Murray, Richard W. Costello, Garrett Greene

Bibliographic record

VenuePhysiological Measurement · 2021
Typearticle
Languageen
FieldMedicine
TopicSepsis Diagnosis and Treatment
Canadian institutionsTrinity College
Fundersnot available
KeywordsRetrospective cohort studyHazard ratioMedicineProportional hazards modelCohortOxygen saturationRespiratory rateCohort studyEmergency medicineRespiratory systemInternal medicineHeart rateConfidence intervalOxygen

Abstract

fetched live from OpenAlex

Abstract Respiratory rate (RR) is routinely used to monitor patients with infectious, cardiac and respiratory diseases and is a component of early warning scores used to predict patient deterioration. However, it is often measured visually with considerable bias and inaccuracy. Objectives . Firstly, to compare distribution and accuracy of electronically measured RR (EMRR) and visually measured RR (VMRR). Secondly, to determine whether, and how far in advance, continuous electronic RR monitoring can predict oncoming hypoxic and pyrexic episodes in infectious respiratory disease. Approach. A retrospective cohort study analysing the difference between EMRR and VMRR was conducted using patient data from a large tertiary hospital. Cox proportional hazards models were used to determine whether continuous, EMRR measurements could predict oncoming hypoxic (SpO 2 < 92%) and pyrexic (temperature >38 °C) episodes. Main results. Data were gathered from 34 COVID-19 patients, from which a total of 3445 observations of VMRR (independent of Hawthorne effect), peripheral oxygen saturation and temperature and 729 117 observations of EMRR were collected. VMRR had peaks in distribution at 18 and 20 breaths per minute. 70.9% of patients would have had a change of treatment during their admission based on the UK’s National Early Warning System if EMRR was used in place of VMRR. An elevated EMRR was predictive of hypoxic (hazard ratio: 1.8 (1.05–3.07)) and pyrexic (hazard ratio: 9.7 (3.8–25)) episodes over the following 12 h. Significance. Continuous EMRR values are systematically different to VMRR values, and results suggest it is a better indicator of true RR as it has lower kurtosis, higher variance, a lack of peaks at expected values (18 and 20) and it measures a physiological component of breathing directly (abdominal movement). Results suggest EMRR is a strong marker of oncoming hypoxia and is highly predictive of oncoming pyrexic events in the following 12 h. In many diseases, this could provide an early window to escalate care prior to deterioration, potentially preventing morbidity and mortality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.008
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.121
GPT teacher head0.339
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicSepsis Diagnosis and TreatmentFrench-language works237,207