Three-dimensional imaging on a chip using optofluidics light-sheet fluorescence microscopy
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Volumetric, sub-micron to micron level resolution imaging is necessary to assay phenotypes or characteristics at the sub-cellular/organelle scale. However, three-dimensional fluorescence imaging of cells is typically low throughput or compromises on the achievable resolution in space and time. Here, we capitalise on the flow control capabilities of microfluidics and combine it with microoptics to integrate light-sheet based imaging directly into a microfluidic chip. Our optofluidic system flows suspended cells through a sub-micrometer thick light-sheet formed using micro-optical components that are cast directly in polydimethylsiloxane (PDMS). This design ensures accurate alignment, drift-free operation, and easy integration with conventional microfluidics, while providing sufficient spatial resolution, optical sectioning and volumetric data acquisition. We demonstrate imaging rates of 120 ms per cell at sub-μm resolution, that allow extraction of complex cellular phenotypes, exemplified by imaging of cell clusters, receptor distribution, and the analysis of endosomal size changes.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it