MétaCan
Menu
Back to cohort
Record W3168455985 · doi:10.18186/thermal.797291

EXPERIMENTAL INVESTIGATION OF AN ALUMINIUM THERMOSYPHON AT NORMAL OPERATING CONDITIONS

2020· article· en· W3168455985 on OpenAlexaff
Sachin Mutalikdesai, Ajit M. Kate

Bibliographic record

VenueJournal of Thermal Engineering · 2020
Typearticle
Languageen
FieldEngineering
TopicHeat Transfer and Boiling Studies
Canadian institutionsTrinity College
Fundersnot available
KeywordsThermosiphonCondenser (optics)EvaporatorMaterials scienceMass flow rateWorking fluidThermodynamicsHeat pipeThermal resistanceHeat transferHeat exchangerMechanicsWater coolingPhysicsOptics

Abstract

fetched live from OpenAlex

The paper presents experimental investigation of an aluminium thermosyphon charged with acetone as working fluid. The effect of filling ratio on steady state performance of thermosyphon is experimentally investigated. Experimentation is performed at three different ratios namely 30 %, 60 % and 100 %. The effect of heat input and mass flow rate of water is also investigated. The heat input is varied between 50 to 300 W and mass flow rate is maintained in the range 30 lph to 60 lph. A condenser section of thermosyphon is surrounded by two pass aluminium cooling block for effective condensation. The cooling block is design in such a way that water will absorbs maximum heat from working fluid in condenser section. The temperature at outer surface of thermosyphon is recorded with the help of temperature sensors. The temperature distribution at outer surface of evaporator and condenser observed to be almost uniform for all mass flow rates and filling ratios. The heat transfer limitations are not encountered for any of thermosyphon. The filling ratio has significant effect on outer surface temperature of evaporator. The surface temperature of evaporator increases by 20 % with increasing the filling ratio at 150 W heat input and 30 lph mass flow rate. The results also indicate that mass flow of cooling water has significant effect on total thermal resistance of thermosyphon at lower input. For 50 W heat input, minimum thermal resistance is recorded as 0.269 °C/W at 60 % filling ratio and 50 lph mass flow rate. While for a same heat input, maximum thermal resistance is recorded as 1.077 °C/W at 100 % filling ratio and 60 lph mass flow rate.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.222
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Thermal EngineeringSame topicHeat Transfer and Boiling StudiesFrench-language works237,207