Multicountry clinical outcomes of a new nondiffractive presbyopia-correcting IOL
Bibliographic record
Abstract
PURPOSE: To evaluate the effectiveness and safety of a new presbyopia-correcting intraocular lens (IOL) with a nondiffractive design, DFT015, compared with an aspheric monofocal IOL, SN60WF. SETTING: 19 investigational sites in 4 countries: Australia, Canada, Spain, and the United Kingdom. DESIGN: Prospective, randomized, parallel-group, controlled, assessor- and patient-masked clinical study. METHODS: Participants aged ≥22 years with bilateral cataracts were randomized to DFT015 or SN60WF in a 5:4 ratio and masked until final postoperative follow-up at month 6. The primary effectiveness objective was superiority of DFT015 over SN60WF in mean monocular photopic distance-corrected intermediate visual acuity (DCIVA) at month 3. Secondary effectiveness objectives included noninferiority of DFT015 to SN60WF in mean monocular photopic corrected distance visual acuity (CDVA) and superiority in the mean monocular photopic distance-corrected near visual acuity (DCNVA) at month 3. Visual disturbances were assessed at month 6. RESULTS: 282 patients were randomized to DFT015 (n = 159) or SN60WF (n = 123). All effectiveness objectives were achieved at month 3 in first eyes. For monocular photopic results in first eyes, DFT015 demonstrated superior mean DCIVA (least squares means of -0.139 logMAR in favor of DFT015, P < .001), noninferior mean CDVA (97.5% upper confidence limit [UCL] of the difference was <0.1 logMAR) and superior mean DCNVA (95% UCL of the difference was <0.0 logMAR) compared with SN60WF at month 6. DFT015 exhibited a similar visual disturbance profile to that of SN60WF. CONCLUSIONS: DFT015 provided superior intermediate and near vision and a similar visual disturbance profile compared with an aspheric monofocal IOL.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".