MétaCan
Menu
Back to cohort
Record W3174244351 · doi:10.1109/access.2021.3090220

Parameter Adjustment for the Droop Control Operating a Discharge PEC in PMG-Based WECSs With Generator-Charged Battery Units

2021· article· en· W3174244351 on OpenAlexafffund
S. A. Saleh, Razzaqul Ahshan

Bibliographic record

VenueIEEE Access · 2021
Typearticle
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsUniversity of New Brunswick
FundersNatural Sciences and Engineering Research Council of CanadaSultan Qaboos University
KeywordsVoltage droopBattery (electricity)Control theory (sociology)ConvertersPower (physics)Computer scienceVoltagePermanent magnet synchronous generatorGridState of chargeAutomotive engineeringGenerator (circuit theory)AC powerElectrical engineeringEngineeringControl (management)Voltage sourcePhysicsMathematics

Abstract

fetched live from OpenAlex

Permanent magnet generator (PMG)-based wind energy conversion systems (WECSs) with battery units, have become a popular class of distributed generation units. These distributed generation units are typically operated using various types of controllers, including droop controllers. Existing droop controllers are designed to operate grid-side dc-ac power electronic converters (PEC) to ensure stable and reliable power production by a PMG-based WECS. The employment of battery storage units (to mitigate fluctuations in the power produced by a PMG-based WECS) introduces additional considerations for the design of droop controllers. Such considerations are due to the power available from battery units that is dependent on the state-of-charge (SOC). This paper proposes adjustments in the parameters (droop constants) of the droop control (operate the the discharge PEC) based on the SOC of the battery units. These adjustments are made to further support stable and reliable power delivery of the PMG-based WECS into the point-of-common-coupling (PCC). The proposed adjustments of droop constants are evaluated using a 7.5 kW grid-connected PMG-based WECS with 3.52 kW generator-charged battery storage units. Performance tests are carried out for step changes in the active and reactive power demands, changes in the wind speed, and grid-side disturbances. Test results show that the proposed correction of the droop constants is critical for maintaining a stable, effective, and accurate power delivery by the battery units, thus supporting the voltage/frequency stability at the PCC under different operating conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.233
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueIEEE AccessSame topicMicrogrid Control and OptimizationFrench-language works237,207