MétaCan
Menu
Back to cohort
Record W3174837023 · doi:10.1115/1.4051527

A Parametric Analysis of Embedded Tissue Marker Properties and Their Effect on the Accuracy of Displacement Measurements

2021· article· en· W3174837023 on OpenAlexafffund
Scott Dutrisac, MacKenzie Brannen, T. Blaine Hoshizaki, Hanspeter Frei, Oren E. Petel

Bibliographic record

VenueJournal of Biomechanical Engineering · 2021
Typearticle
Languageen
FieldMedicine
TopicAutomotive and Human Injury Biomechanics
Canadian institutionsUniversity of OttawaCarleton University
FundersCanadian Institutes of Health ResearchCanada Foundation for Innovation
KeywordsStiffnessBiomedical engineeringParametric statisticsDisplacement (psychology)Materials scienceBiological systemComputer scienceMathematicsComposite materialMedicineBiologyStatistics

Abstract

fetched live from OpenAlex

Datasets obtained from cadaveric experimentation are broadly used in validating finite element models of head injury. Due to the complexity of such measurements in soft tissues, experimentalists have relied on tissue-embedded radiographic or sonomicrometry tracking markers to resolve tissue motion caused by impulsive loads. Dynamic coupling of markers with the surrounding tissue has been a previous concern, yet a thorough sensitivity investigation of marker influences on tissue deformation has not been broadly discussed. Technological improvements to measurement precision have bolstered confidence in acquired data; however, precision is often conflated with accuracy; the inclusion of markers in the tissue may alter its natural response, resulting in a loss of accuracy associated with an altered displacement field. To gain an understanding of how marker properties may influence the measured response to impact, we prepared a set of nine marker designs using a Taguchi L9 array to investigate marker design choice sensitivity. Each of these designs was cast into a block of tissue simulant and subjected to repeated drop tests. Vertical displacement was measured and compared to the response of the neat material, which contained massless tracking markers. Medium density and medium stiffness markers yielded the least deviation from the neat material response. The results provide some design guidelines indicating the importance of maintaining marker matrix density ratio below 1.75 and marker stiffness below 1.0 MPa. These properties may minimize marker interference in tissue deformation. Overall, embedded marker properties must be considered when measuring the dynamic response of tissue.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.012
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.279
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicAutomotive and Human Injury BiomechanicsFrench-language works237,207