MétaCan
Menu
Back to cohort
Record W3177201125 · doi:10.1002/mp.15058

Feasibility of attenuation map alignment in pinhole cardiac SPECT using exponential data consistency conditions

2021· article· en· W3177201125 on OpenAlexaff
R. Glenn Wells, Rolf Clackdoyle

Bibliographic record

VenueMedical Physics · 2021
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of Ottawa
FundersAgence Nationale de la Recherche
KeywordsAttenuationCorrection for attenuationImaging phantomScannerSpect imagingPinhole (optics)DetectorData consistencyNuclear medicineIterative reconstructionSingle-photon emission computed tomographyComputer scienceArtificial intelligenceComputer visionOpticsPhysicsMedicine

Abstract

fetched live from OpenAlex

PURPOSE: Dedicated cardiac SPECT systems do not typically include an integrated CT scanner and thus attenuation correction requires registration of separately acquired transmission scans. Data consistency conditions are equations that express the redundancy between projections while taking into account the attenuation effects. This study assessed the feasibility of applying exponential data consistency conditions to rebinned pinhole projections for attenuation-map registration in pinhole cardiac SPECT. METHODS: Simulations of an anthropomorphic computer phantom with three different tracer activity distributions were performed with and without clinical levels of noise in the projection data. The first activity distribution contained activity only within the myocardium which satisfied the assumptions of the data consistency conditions. The other two distributions violated these assumptions by adding background activity and uptake in the liver. Simulations included acquisitions with 360, 31, and 9 pinhole projections and detector pixel sizes of 0.75 and 2.5 mm. A metric based on the average difference between pairs of exponential projections was used to evaluate registration accuracy. RESULTS: When activity is restricted to the myocardium, the registration error was 3.0 mm for 31 noisy pinhole projections with a detector size of 2.5 mm. When activity is added to the background and the liver, a correction for the extra-cardiac activity is needed but when applied, a registration error of 6.0 mm was achieved. CONCLUSION: These results suggest that it may be feasible to use exponential data consistency conditions to register pinhole cardiac SPECT and CT transmission data. Taxonomy: 8-6 (IM-SPECT/Registration).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.024
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.024
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.122
GPT teacher head0.399
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207