MétaCan
Menu
Back to cohort
Record W3178776181 · doi:10.3390/cleantechnol3030031

Sensing and Delineating Mixed-VOC Composition in the Air Using a Single Metal Oxide Sensor

2021· article· en· W3178776181 on OpenAlexaff
Govind S. Thakor, Ning Zhang, Rafael M. Santos

Bibliographic record

VenueClean Technologies · 2021
Typearticle
Languageen
FieldEngineering
TopicAdvanced Chemical Sensor Technologies
Canadian institutionsUniversity of Guelph
Fundersnot available
KeywordsPollutantAcetoneVolatile organic compoundOxideSensor arrayCalibrationEnvironmental scienceExtraction (chemistry)Environmental chemistryBiological systemChemistryAnalytical Chemistry (journal)ChromatographyComputer scienceOrganic chemistryMathematicsStatistics

Abstract

fetched live from OpenAlex

Monitoring volatile organic compounds (VOCs) places a crucial role in environmental pollutants control and indoor air quality. In this study, a metal-oxide (MOx) sensor detector (used in a commercially available monitor) was employed to delineate the composition of air containing three common VOCs (ethanol, acetone, and hexane) under various concentrations. Experiments with a single component and double components were conducted to investigate how the solvents interact with the metal oxide sensor. The experimental results revealed that the affinity between VOC and sensor was in the following order: acetone > ethanol > n-hexane. A mathematical model was developed, based on the experimental findings and data analysis, to convert the output resistance value of the sensor into concentration values, which, in turn, can be used to calculate a VOC-based air quality index. Empirical equations were established based on inferences of vapour composition versus resistance trends, and on an approach of using original and diluted air samples to generate two sets of resistance data per sample. The calibration of numerous model parameters allowed matching simulated curves to measured data. Therefore, the predictive mathematical model enabled quantifying the total concentration of sensed VOCs, in addition to estimating the VOC composition. This first attempt to obtain semiquantitative data from a single MOx sensor, despite the remaining selectivity challenges, is aimed at expanding the capability of mobile air pollutants monitoring devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.001

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.229
Teacher spread0.209 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueClean TechnologiesSame topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207