MétaCan
Menu
Back to cohort
Record W3180547509 · doi:10.1111/jce.15153

Safety and feasibility of left bundle branch area pacing following valvular interventions: Multicenter study

2021· article· en· W3180547509 on OpenAlexaff
Enes Elvin Gül, Rajiv A. Kabadi, Santosh K. Padala, Paula Sánchez-Somonte, Jordana Kron, Richard K. Shepard, Jayanthi N. Koneru, Gautham Kalahasty, María Terricabras, Bernice Tsang, Yaariv Khaykin, Zaev Wulffhart, Alfredo Pantano, Kenneth A. Ellenbogen, Atul Verma

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSouthlake Regional Health CenterUniversity of Toronto
Fundersnot available
KeywordsMedicineImplantCardiologyPercutaneousQRS complexInternal medicineAtrioventricular blockEjection fractionSurgeryvalvular heart diseaseHeart failure

Abstract

fetched live from OpenAlex

OBJECTIVES: To evaluate the safety and feasibility of left bundle branch area pacing (LBBAP) in patients with valvular interventions. METHODS: Eighty-four patients were included in this study. All patients underwent recent surgical or percutaneous valvular interventions. LBBAP was attempted in all patients. Implant success rates, peri- and postprocedure electrocardiogram, pacing parameters, and complications were assessed at implant, and during follow-up. RESULTS: LBBAP implantation was successful in 80/84 (95%) patients. Mean age was 74.1 ± 13.8 years and 56% patients were male. Prior valvular replacements included: percutaneous aortic (26), surgical aortic (36), combined surgical aortic plus mitral (6), MVR (10), tricuspid (1), and pulmonic (1). Average LVEF was 52.6 ± 11%. Majority of patients underwent LBBAP due to atrioventricular block (76%) and sinus node disease (13%). Total procedure duration was 74.1 ± 12.5 min and fluoroscopic duration was 9.7 ± 6.8 min. Pacing parameters were stable during follow-up period of 10.0 ± 6.3 months. Pacing QRS duration was significantly narrower than baseline QRS duration (131.5 ± 31.4 ms vs. 114.3 ± 13.7 ms, p < .001, respectively). No acute complications were observed. Mean follow-up was 10.0 ± 6.3 months (median: 8.4 months, min: 1 and max: 24 months). During follow-up, there were three device infections and two patients had loss of LBBA capture within 1 month of implant. CONCLUSIONS: LBBAP is a feasible and safe pacing modality in patients with prior interventions for valvular heart disease.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.007
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.319
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207