MétaCan
Menu
Back to cohort

Optimization of Blood Microfluidic Co-Flow Devices for Dual Measurement

2021· article· en· W3182026559 on OpenAlexaff
Amit Nayak, Curtis Armstrong, Catherine Mavriplis, Marianne Fenech

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsMicrofluidicsVolumetric flow rateShearing (physics)Materials scienceShear rateBlood flowFlow velocityShear stressShear flowFlow (mathematics)Biomedical engineeringMechanicsNanotechnologyComposite materialRheologyEngineeringPhysics

Abstract

fetched live from OpenAlex

Microfluidics is a prominent field used to analyze small amounts of biological fluids. Co-Flow microfluidic devices can be used to study red blood cell aggregation in blood samples under a controlled shear rate. The purpose of this paper is to optimize the parameters of a co-flow device in order to produce a linear velocity profile in blood samples which would provide a constant shear rate. This is desired as the eventual goal is to use an ultrasonic measurement sensor with the co-flow microfluidic device to analyze red blood cell aggregates. Computational fluid dynamic simulations were performed to model a microfluidic device. The simulation results were verified by μPIV of the experimental microfluidic device. Modifications were made to the geometry and flow rate ratio of the microfluidic device to produce a more linear velocity profile. By using a flow rate ratio of 50:1 of shearing fluid to sheared fluid, we were able to achieve a velocity profile in the blood layer that is approximately linear.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.215
Teacher spread0.200 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes1
Has abstractyes

Explore more

Same topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207