MétaCan
Menu
Back to cohort
Record W3186144593 · doi:10.1002/acm2.13342

Alert system for monitoring changes in patient anatomy during radiation therapy of head and neck cancer

2021· article· en· W3186144593 on OpenAlexaff
B Schaly, Jeff Kempe, Varagur Venkatesan, Sylvia Mitchell, Jeff Chen

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2021
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsWestern UniversityCancer Care Ontario
Fundersnot available
KeywordsMedicineFalse positive paradoxHead and neckCone beam computed tomographyHead and neck cancerRadiation therapyMedical physicsRadiation treatment planningNuclear medicineRadiologyComputed tomographySurgeryComputer scienceArtificial intelligence

Abstract

fetched live from OpenAlex

The purpose of this study is to validate a previously developed algorithm for alerting clinicians when to consider re-CT simulation due to changes in the patient's anatomy during radiation therapy of head and neck cancer. Cone beam computed tomography (CBCT) data were collected prospectively for 77 patients. Each CBCT was mathematically compared to a reference CBCT using the gamma index. We defined the match quality parameter (MQP) as an indicator of CBCT image similarity, where a negative MQP value indicates a poorer CBCT match than the match between the first two CBCT acquired during treatment. If three consecutive MQP values were below a chosen threshold, an "alert" is triggered to indicate action required, for example, possible re-CT simulation. The timing of image review requests made by the radiation therapists and any re-CT/re-plan decisions were documented for each patient's treatment course. The MQP for each patient (including any re-plans) was calculated in a manner that was blinded from the clinical process. The MQP as a function of fraction number was compared to actual clinical decisions in the treatment progress to evaluate alert system performance. There was a total of 93 plans (including re-plans) with 34 positives (action required) and 59 negatives (no action required). The sensitivity of the alert system was 0.76 and the false positive rate was 0.37. Only 1 case out of the 34 positive cases would have been missed by both the alert system and our clinical process. Despite the false negatives and false positives, analysis of the timing of alert triggers showed that the alert system could have resulted in seven fewer clinical misses. The alert system has the potential to be a valuable tool to complement human judgment and to provide a quality assurance safeguard to help improve the delivery of radiation treatment of head and neck cancer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.886
Threshold uncertainty score0.370

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.373
Teacher spread0.348 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207