Novel ways to use sensor data to improve mastitis management
Bibliographic record
Abstract
Current sensor systems are used to detect cows with clinical mastitis. Although, the systems perform well enough to not negatively affect the adoption of automatic milking systems, the performance is far from perfect. An important advantage of sensor systems is the availability of multiple measurements per day. By clearly defining the need for detection of subclinical mastitis (SCM) and clinical mastitis (CM) from the farmers' management perspective, detection and management of SCM and CM may be improved. Sensor systems may also be used for other aspects of mastitis management. In this paper we have defined 4 mastitis situations that could be managed with the support of sensor systems. Because of differences in the associated management and the epidemiology of these specific mastitis situations, the required demands for performance of the sensor systems do differ. The 4 defined mastitis situations with the requirements of performance are the following: (1) Cows with severe CM needing immediate attention. Sensor systems should have a very high sensitivity (>95% and preferably close to 100%) and specificity (>99%) within a narrow time window (maximum 12 h) to ensure that close to all cows with true cases of severe CM are detected quickly. Although never studied, it is expected that because of the effects of severe CM, such a high detection performance is feasible. (2) Cows with mastitis that do not need immediate attention. Although these cows have a risk of progressing into severe CM or chronic mastitis, they should get the chance to cure spontaneously under close monitoring. Sensor alerts should have a reasonable sensitivity (>80%) and a high specificity (>99.5%). The time window may be around 7 d. (3) Cows needing attention at drying off. For selective dry cow treatment, the absence or presence of an intramammary infection at dry-off needs to be known. To avoid both false-positive and false-negative alerts, sensitivity and specificity can be equally high (>95%). (4) Herd-level udder health. By combining sensor readings from all cows in the herd, novel herd-level key performance indicators can be developed to monitor udder health status and development over time and raise alerts at significant deviances from predefined thresholds; sensitivity should be reasonably high, >80%, and because of the costs for further analysis of false-positive alerts, the specificity should be >99%. The development and validation of sensor-based algorithms specifically for these 4 mastitis situations will encourage situation-specific farmer interventions and operational udder health management.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.004 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.002 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.002 | 0.003 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.004 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".