MétaCan
Menu
Back to cohort
Record W3189408071 · doi:10.2460/javma.259.5.518

Self-reported radiation safety behaviors among veterinary specialists and residents performing fluoroscopic procedures on small animals

2021· article· en· W3189408071 on OpenAlexaff
Fernando P. Freitas, Niels Koehncke, Cheryl Waldner, Brian A. Scansen, Alexandra Frey Belotta, Kursten V. Pierce, Elissa Randall, Anthony P. Carr, Koji Aoki, Monique N Mayer

Bibliographic record

VenueJournal of the American Veterinary Medical Association · 2021
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of Saskatchewan
Fundersnot available
KeywordsFluoroscopyMedicineMedical physicsRadiation protectionRadiation exposureRadiological weaponPatient safetyVeterinary medicineFamily medicineRadiologyNuclear medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: To describe the radiation safety behaviors of veterinary specialists performing small animal fluoroscopic procedures and examine potential risk factors for these behaviors, including knowledge of radiation risk and training regarding machine operating parameters. SAMPLE: 197 veterinary specialists and residents in training. PROCEDURES: An electronic questionnaire was distributed to members of the American Colleges of Veterinary Internal Medicine (subspecialties of cardiology and small animal internal medicine), Veterinary Radiology, and Veterinary Surgery. RESULTS: The overall survey response rate was 6% (240/4,274 email recipients). Of the 240 respondents, 197 (82%) had operated an x-ray unit for a small animal fluoroscopic procedure in the preceding year and fully completed the questionnaire. More than 95% of respondents believed that radiation causes cancer, yet approximately 60% of respondents never wore hand or eye protection during fluoroscopic procedures, and 28% never adjusted the fluoroscopy machine operating parameters for the purpose of reducing their radiation dose. The most common reasons for not wearing eye shielding included no requirement to wear eyeglasses, poor fit, discomfort, and interference of eyeglasses with task performance. Respondents who had received training regarding machine operating parameters adjusted those parameters to reduce their radiation dose during procedures significantly more frequently than did respondents who had not received training. CONCLUSIONS AND CLINICAL RELEVANCE: On the basis of the self-reported suboptimal radiation safety practices among veterinary fluoroscopy users, we recommend formal incorporation of radiation safety education into residency training programs. All fluoroscopy machine operators should be trained regarding the machine operating parameters that can be adjusted to reduce occupational radiation exposure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.081
Threshold uncertainty score0.502

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.314
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the American Veterinary Medical AssociationSame topicRadiation Dose and ImagingFrench-language works237,207