MétaCan
Menu
Back to cohort
Record W3190562973 · doi:10.1117/12.2594613

A scalable digital microfluidic platform for automation of onsite testing of dairy samples

2021· article· en· W3190562973 on OpenAlexaff
Rahul Eswar, C. Harrison Brodie, Christopher M. Collier

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicElectrowetting and Microfluidic Technologies
Canadian institutionsUniversity of British ColumbiaUniversity of Guelph
Fundersnot available
KeywordsDigital microfluidicsMicrofluidicsScalabilityOptofluidicsElectrowettingInterface (matter)Lab-on-a-chipNanotechnologyMaterials scienceComputer scienceComputer hardwareEmbedded systemEngineeringVoltageElectrical engineering

Abstract

fetched live from OpenAlex

Antibiotic residues are regulated in commercially produced milk, with elevated concentrations being harmful. Detection of these antibiotic residues in milk pose a significant challenge for supply chain stakeholders due to the industry standard practice of low-interval off-site laboratory testing. This practice poses risk of non-compliant milk going undetected during on-site milk collection. On-site microfluidic technologies with integrated optical sensors are positioned to mitigate this challenge using increased screening intervals. Droplet-based (digital) microfluidic systems show promise to provide highthroughput screening in dairy applications with integrated fluorescence spectroscopy technologies. However, conventional digital microfluidic systems are subject to biofouling from the protein and fat content within milk. In this work, a biofouling-resistant digital microfluidic platform is introduced. The digital microfluidic platform leverages advancements in parafilm layers, and is demonstrated with actuation of milk and water microdroplets. Electrowetting-based microdroplet actuation is achieved via scalable grid arrays of uniplanar printed surface electrodes in open and closed system configurations. For this array technology, a reconfigurable firmware is developed for user control of automated microdroplet actuation at up to three hundred volts using a graphical computer interface. An exposition of the microdroplet actuation performance is demonstrated and assessed through an optical system for closed-open feedback and positioning of microdroplets. This optical closed-loop allows the actuation velocity of microdroplets to be characterized for polydimethylsiloxane and parafilm dielectric layers, for both water and milk as a function of frequency and voltage. Scalability and automation of the microfluidic platform is discussed, and future integration of fluorescence spectroscopy is investigated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.047
Threshold uncertainty score0.332

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.219
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes1
Has abstractyes

Explore more

Same topicElectrowetting and Microfluidic TechnologiesFrench-language works237,207