MétaCan
Menu
Back to cohort
Record W3191213533 · doi:10.1002/mp.15154

Improving digital charge sharing compensation in photon counting detectors with a low‐threshold comparator

2021· article· en· W3191213533 on OpenAlexaff
Scott S. Hsieh, Kris Iniewski

Bibliographic record

VenueMedical Physics · 2021
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsRedlen Technologies (Canada)
Fundersnot available
KeywordsCharge sharingPhysicsComparatorPhoton countingNoise (video)PhotonMonte Carlo methodPixelPoisson distributionDetectorOpticsComputational physicsStatisticsComputer scienceVoltageMathematicsArtificial intelligence

Abstract

fetched live from OpenAlex

PURPOSE: Charge sharing is a major non-ideality in photon counting detectors (PCDs) and can increase variance in material decomposition images. Analog charge summing (ACS) is an effective mechanism for charge sharing compensation (CSC), but is complex to implement and may limit the maximum count rate of the PCD. Digital CSC mechanisms such as digital count summing (DCS) may be simpler to implement; however, earlier simulation studies suggest that digital CSC only provides half the benefit of ACS. We propose including an additional low-threshold comparator (LTC) underneath the noise floor of the PCD to improve the effectiveness of digital CSC. METHODS: We simulated a PCD with four or eight equally spaced energy bins. X-ray photons arrived on the PCD following a Poisson distribution, and charge was allocated to PCD pixels following Monte Carlo techniques. Gaussian electronic noise was added with standard deviation of 2 keV and the signals were processed with four CSC schemes: no CSC, ACS, DCS, and DCS with LTC. The energy bins were placed from 25 to 100 keV at 25 keV intervals (for four bins) or from 25 to 112.5 keV at 12.5 keV intervals (for eight bins), and the LTC threshold was placed at 8 keV in both cases. The binned counts were transformed into estimates of water and iodine material thickness using a linear estimator that was fitted to the data. Our simulations were performed in the low-flux limit without any pileup, assuming a 120 kVp spectrum, 25 cm water object, and 0.3 mm PCD pixel size. RESULTS: All CSC schemes decreased variance in basis material decomposition. In the four-bin PCD, the relative dose efficiencies (inverse of the variance) for iodine material decomposition were 1.0, 2.4, 3.2, and 4.3 for a PCD without CSC, DCS without LTC, DCS with LTC, and ACS, respectively. In the eight-bin PCD, the relative dose efficiencies were 1.1, 2.5, 3.1, and 4.8, respectively. In a sensitivity analysis, electronic noise had a stronger deleterious effect on ACS than DCS. In simulated visual images, DCS and ACS improved high frequency contrast in material decomposition images. CONCLUSIONS: Introducing an LTC may reduce the performance differential between DCS and ACS. These findings have been derived from simulation studies only and have not been validated experimentally.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.737
Threshold uncertainty score0.614

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.212
Teacher spread0.205 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207