MétaCan
Menu
Back to cohort
Record W3191334052 · doi:10.1088/1361-6560/ac1d1e

Patient-specific microdosimetry: a proof of concept

2021· article· en· W3191334052 on OpenAlexafffund
Joseph M. DeCunha, Fernanda Villegas, Martin Vallières, José Torres, Sophie Camilleri‐Broët, Shirin A. Enger

Bibliographic record

VenuePhysics in Medicine and Biology · 2021
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsJewish General HospitalMcGill University Health CentreUniversité de SherbrookeMcGill University
FundersFonds de Recherche du Québec - SantéCanada Research Chairs
KeywordsIonizing radiationNucleusRelative biological effectivenessRADIUSNuclear medicineSpecific energyRadiationLinear energy transferIrradiationPhysicsNuclear physicsComputer scienceBiologyMedicineThermodynamics

Abstract

fetched live from OpenAlex

Abstract Microscopic energy deposition distributions from ionizing radiation vary depending on biological target size and are used to predict the biological effects of an irradiation. Ionizing radiation is thought to kill cells or inhibit the cell cycle mainly by damaging DNA in the cell nucleus. The size of cells and nuclei depends on tissue type, cell cycle, and malignancy, all of which vary between patients. The aim of this study was to develop methods to perform patient-specific microdosimetry, that being, determining microdosimetric quantities in volumes that correspond to the sizes of cells and nuclei observed in a patient’s tissue. A histopathological sample extracted from a stage I lung adenocarcinoma patient was analyzed. A pouring simulation was used to generate a three-dimensional tissue model from cell and nucleus size information determined from the histopathological sample. Microdosimetric distributions including f ( y ) and d ( y ) were determined for C 60 o , I 192 r , Y 169 b and I 125 in a patient-specific model containing a distribution of cell and nucleus sizes. Fixed radius models and a summation method were compared to the full patient-specific model to evaluate their suitability for fast determination of patient-specific microdosimetric parameters. In the summation method, f(y) from many fixed radii models are summed. Fixed radius models do not provide a close approximation of the full patient-specific model y ¯ f or y ¯ d for the lower energy sources investigated, Y 169 b and I 125 . The higher energy sources investigated, C 60 o and

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.114
GPT teacher head0.361
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2021
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiation Therapy and DosimetryFrench-language works237,207