MétaCan
Menu
Back to cohort

Multi-View 3-D Fusion Echocardiography: Enhancing Clinical Feasibility with a Novel Processing Technique

2021· article· en· W3191553295 on OpenAlexaff
Tyler Lamb, Victoria Sarban, Miriam Shanks, Eila Mirhadi, Abhilash Rakkunedeth Hareendranathan, Michelle Noga, Kumaradevan Punithakumar, Pierre Boulanger, Harald Becher

Bibliographic record

VenueUltrasound in Medicine & Biology · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Alberta
FundersServier
KeywordsEjection fractionMedicineCardiologyInternal medicineDiastoleSystoleOrientation (vector space)RadiologyHeart failureMathematicsBlood pressure

Abstract

fetched live from OpenAlex

A novel system for fusing 3-D echocardiography data sets from complementary acoustic windows was evaluated in 12 healthy volunteers and 12 patients with heart failure. We hypothesized that 3-D fusion would enable 3-D echocardiography in patients with limited acoustic windows. At least nine 3-D data sets were recorded, while three infrared cameras tracked the position and orientation of the transducer and chest respiratory movements. Corresponding 2-D planes of the fused 3-D data sets and of single-view 3-D data sets were assessed for image quality and compared with measurements of left ventricular function obtained with contrast 2-D echocardiography. The signal-to-noise ratio in accurately fused 3-D echocardiography recordings improved by 55% in systole (p < 0.001) and 47% in diastole (p < 0.00001) compared with the apical single-view recordings. The 3-D data sets acquired during short breath holds were successfully fused in 11 of 12 patients. The improvement in endocardial border definition (from 11.7 ± 6.0 to 24.0 ± 3.3, p < 0.01) enabled quantitative assessment of left ventricular function in 10 patients, with no significant difference in ejection fraction compared with contrast 2-D echocardiography. In patients with heart failure and limited acoustic windows, the novel fusion protocol provides 3-D data sets suitable for quantitative analysis of left ventricular function.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.387
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueUltrasound in Medicine & BiologySame topicCardiac Imaging and DiagnosticsFrench-language works237,207