MétaCan
Menu
Back to cohort
Record W3194856501 · doi:10.1177/08465371211031186

The Impact of Radiologist Screening Mammogram Reading Volume on Performance in the Ontario Breast Screening Program

2021· article· en· W3194856501 on OpenAlexaffabout
Meghan J. Walker, Krystal Hartman, Vicky Majpruz, Yvonne Leung, Samantha Fienberg, Linda Rabeneck, Anna M. Chiarelli

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2021
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsGrand River HospitalCancer Care OntarioMcMaster UniversityEntomological Society of CanadaPublic Health OntarioUniversity of Toronto
Fundersnot available
KeywordsMedicineMammographyLogistic regressionBreast cancer screeningRetrospective cohort studyDigital mammographyBreast cancerScreening mammographyMultivariate analysisPredictive valueRadiologyCancerInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: Although some studies have shown increasing radiologists' mammography volumes improves performance, there is a lack of evidence specific to digital mammography and breast screening program performance targets. This study evaluates the relationship between digital screening volume and meeting performance targets. METHODS: This retrospective cohort study included 493 radiologists in the Ontario Breast Screening Program who interpreted 1,762,173 screening mammograms in participants ages 50-90 between 2014 and 2016. Associations between annual screening volume and meeting performance targets for abnormal call rate, positive predictive value (PPV), invasive cancer detection rate (CDR), sensitivity, and specificity were modeled using mixed-effects multivariate logistic regression. RESULTS: Most radiologists read 500-999 (36.7%) or 1,000-1,999 (31.0%) screens annually, and 18.5% read ≥2,000. Radiologists who read ≥2,000 annually were more likely to meet abnormal call rate (OR = 3.85; 95% CI: 1.17-12.61), PPV (OR = 5.36; 95% CI: 2.53-11.34), invasive CDR (OR = 4.14; 95% CI: 1.50-11.46), and specificity (OR = 4.07; 95% CI: 1.89-8.79) targets versus those who read 100-499 screens. Radiologists reading 1,000-1,999 screens annually were more likely to meet PPV (OR = 2.32; 95% CI: 1.22-4.40), invasive CDR (OR = 3.36; 95% CI: 1.49-7.59) and specificity (OR = 2.00; 95% CI: 1.04-3.84) targets versus those who read 100-499 screens. No significant differences were observed for sensitivity. CONCLUSIONS: Annual reading volume requirements of 1,000 in Canada are supported as screening volume above 1,000 was strongly associated with achieving performance targets for nearly all measures. Increasing the minimum volume to 2,000 may further reduce the potential limitations of screening due to false positives, leading to improvements in overall breast screening program quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.135
Threshold uncertainty score0.970

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.272
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicDigital Radiography and Breast ImagingFrench-language works237,207