Clinically Delivered Treatment for Glioma Patients on a Hybrid Magnetic Resonance Imaging (MRI)-Linear Accelerator (MR-Linac) and a Cone Beam CT (CBCT)-Guided Linac: Dosimetric Comparisons with In Vivo Skin Dose Correlation

2021· preprint· en· W3195339042 on OpenAlexaff
Michael H. Wang, Anthony Kim, Mark Ruschin, Hendrick Tan, Hany Soliman, Sten Myrehaug, Jay Detsky, Zain Husain, Eshetu G. Atenafu, Brian Keller, Arjun Sahgal, Chia‐Lin Tseng

Bibliographic record

VenueResearch Square · 2021
Typepreprint
Languageen
FieldMedicine
TopicGlioma Diagnosis and Treatment
Canadian institutionsUniversity Health NetworkHealth Sciences CentreSunnybrook Health Science Centre
FundersAccurayElekta
KeywordsLinear particle acceleratorNuclear medicineMagnetic resonance imagingMedicineCone beam ctBeam (structure)Medical physicsRadiologyPhysicsOpticsComputed tomography

Abstract

fetched live from OpenAlex

Abstract Background Magnetic Resonance Imaging (MRI)-Linear Accelerator (MR-Linac) radiotherapy requires special consideration for secondary electron interactions within the magnetic field, which can alter dose deposition at air-tissue interfaces. Methods Thirty-seven consecutive glioma patients treated during their radiotherapy course with at least one fraction delivered on MR-Linac or Cone Beam CT (CBCT)-guided Linac, were analyzed. Treatment planning for both systems were completed prior to radiotherapy initiation and approved for clinical delivery using commercial treatment planning systems (TPS): a Monte Carlo calculation-based or convolution calculation-based TPS for MR-Linac or CBCT-Linac, respectively. Dosimetric parameters for planning target volume (PTV), organs-at-risk (OARs), and air-tissue interface were compared. In vivo skin dose during a single fraction of MR-Linac and CBCT-Linac treatment was measured using an Optically Stimulated Luminescent Dosimeter (OSLD) and correlated with TPS skin dose. Results Monte Carlo-based MR-Linac plans and convolution-based CBCT-Linac plans exhibited minimal differences in PTV and OAR parameters. However, MR-Linac plans had greater doses within tissues surrounding air cavities (1.52 Gy higher mean Dmean, p < 0.0001) and skin (1.10 Gy higher mean Dmean, p < 0.0001). In vivo OSLD skin readings were 14.5% greater for MR-Linac treatments (p = 0.0027), and were more accurately predicted by Monte Carlo-based calculation (ρ = 0.95, p < 0.0001) vs. convolution-based (ρ = 0.80, p = 0.0096). Conclusions The magnetic field’s dosimetric impact was minimal for PTV and OARs in glioma as compared to standard CBCT-Linac treatment plans. However, skin doses were significantly greater with the MR-Linac and correlated with in vivo measurements. Future MR-Linac planning processes are being designed to account for skin dosimetry and treatment delivery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.067
GPT teacher head0.386
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueResearch Square→Same topicGlioma Diagnosis and Treatment→French-language works237,207→