MétaCan
Menu
Back to cohort
Record W3195433076 · doi:10.1016/j.drugpo.2021.103409

Portable gas chromatography–mass spectrometry in drug checking: Detection of carfentanil and etizolam in expected opioid samples

2021· article· en· W3195433076 on OpenAlexafffundabout
Lea Gozdzialski, Jarred Aasen, Ashley Larnder, Margo Ramsay, Scott A. Borden, Armin Saatchi, Chris G. Gill, Bruce Wallace, Dennis K. Hore

Bibliographic record

VenueInternational Journal of Drug Policy · 2021
Typearticle
Languageen
FieldPharmacology, Toxicology and Pharmaceutics
TopicForensic Toxicology and Drug Analysis
Canadian institutionsVancouver Island UniversitySimon Fraser UniversityUniversity of Victoria
FundersNatural Sciences and Engineering Research Council of CanadaHealth CanadaVancouver Island UniversityVancouver FoundationWestern Canada Research GridCompute CanadaUniversity of Victoria
KeywordsFentanylChromatographyMass spectrometryGas chromatography–mass spectrometryChemistryMedicinePharmacology

Abstract

fetched live from OpenAlex

BACKGROUND: There has been a recent increase in adulteration of opioids with low concentration actives such as fentanyl analogues and benzodiazepines. As drug checking projects using vibrational spectroscopy continue to seek confirmatory lab-based testing, the concern and reality of missing these potentially harmful substances in point-of-care testing is prevalent. METHODS: A portable GC-MS was used to analyze select opioid samples acquired at a drug checking service in Victoria, Canada (n=59). Certified reference standards of several fentanyl analogues and benzodiazepines were measured to guide targeted analysis of these samples. Results were compared with those obtained using a lab-based paper spray mass spectrometer. RESULTS: Portable GC-MS was able to identify 62% of samples containing carfentanil and 36% of samples containing etizolam. In the case of etizolam, the success rate was higher for more potent samples: 78% of etizolam-containing samples were identified when the etizolam concentration was above 3% by weight. In comparison, infrared spectroscopy was able to detect etizolam in only 9% of the etizolam-containing samples, and is not sensitive enough to detect carfentanil at relevant concentrations. CONCLUSIONS: Portable GC-MS has potential in identifying low concentration substances in a point-of-care setting, without relying on subsequent off-site confirmatory testing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.291
Threshold uncertainty score0.696

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.381
Teacher spread0.350 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations51
Published2021
Admission routes3
Has abstractyes

Explore more

Same venueInternational Journal of Drug PolicySame topicForensic Toxicology and Drug AnalysisFrench-language works237,207