Commentary: Is it time to revisit the arterial pressure monitoring site for cardiac surgery?
Bibliographic record
Abstract
Central MessageCurrent research confirms that radial artery pressure measurement is associated with radial-to-femoral pressure gradient in cardiac surgery and smaller radial artery diameter is a risk factor.See Article page 446. Current research confirms that radial artery pressure measurement is associated with radial-to-femoral pressure gradient in cardiac surgery and smaller radial artery diameter is a risk factor. See Article page 446. Radial arterial catheterization has historically been the most common form of invasive arterial blood pressure monitoring used during surgical procedures and in the intensive care units. It is relatively safe due to collateral blood supply to the hand, and can reflect dynamic changes in blood pressure on a continuous basis. Bouchard-Dechêne and colleagues1Bouchard-Dechêne V. Kontar L. Couture P. Pérusse P. Levesque S. Lamarche Y. et al.Montreal Heart Institute Research TeamRadial-to-femoral pressure gradient quantification in cardiac surgery.J Thorac Cardiovasc Surg Open. 2021; 8: 446-460Scopus (4) Google Scholar explore the accuracy of blood pressure monitoring during cardiac surgery when radial arterial cannulation is utilized. In a nonrandomized and unadjusted analysis, the authors found significant radial-to-femoral pressure gradient in more than one-third of patients undergoing cardiac surgery and proposed the size of the radial artery as a potential risk factor. Patients with radial artery diameter <1.8 mm had higher frequency (up to 48%) and duration of the pressure gradient than those whose arterial diameter was larger. The authors report substantial difference in the measured pressure and vasopressor use that can result as a consequence of cardiopulmonary bypass (CPB) between radial and femoral arterial measurements. In this observational study, the decision about the site of the arterial catheter is left to the discretion of the anesthesiologist. The authors report no difference in the comorbidities and procedure type between patients who had radial artery catheter versus radial + femoral catheter. Yet, intraoperative characteristics, such as duration of CPB, aortic clamp time, combined procedures, and “ease of separation” from CPB suggest that patients who had dual arterial line monitoring had more complex and involving procedures. This brings the question that there is some selection process when the decision was made about pressure monitoring strategy, and that the groups are not similar. The fact that the study is prone to selection bias and the anesthesiologist practice is not adjusted for, should be acknowledged. With this all-too-common scenario of underestimation of true arterial pressure with radial artery catheters, would it not be better to avoid it altogether? What would be the alternative? Double arterial cannulation for blood pressure monitoring can alleviate a radial arterial underestimation intraoperatively but introduces additional risk for the patient, also requires an operator (either the surgeon or anesthesiologist) to switch from their current task to perform the procedure, along with postoperative concerns for mobilization, infection, and bleeding risks. Many patients are started on anticoagulation on first postoperative day for various reasons, which puts the patient at risk of bleeding and thigh hematoma if the femoral arterial line is removed after anticoagulation was started. Brachial arterial catheters for pressure monitoring have been feared historically for the concern of arterial thrombosis of an end artery leading to arm ischemia. Brachial arterial cannulation alleviates the need for 2 separate procedures by providing reliable accuracy of central arterial pressure immediately after CPB unlike radial artery catheterizations, and also mitigates the risks from 2 procedures to the patient.2Scheer B. Perel A. Pfeiffer U. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.Crit Care. 2002; 6: 199Crossref PubMed Google Scholar,3Bazaral M.G. Welch M. Golding L.A. Badhwar K. Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery.Anesthesiology. 1990; 73: 38-45Crossref PubMed Scopus (61) Google Scholar At our institution, we have experienced the safety and efficacy of utilizing brachial arterial catheters for both routine and complex cardiac surgical cases while the risk of complications remains low (complication rate requiring intervention is 0.26% with brachial artery cannulation).3Bazaral M.G. Welch M. Golding L.A. Badhwar K. Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery.Anesthesiology. 1990; 73: 38-45Crossref PubMed Scopus (61) Google Scholar In addition, we also see good longevity and accuracy from these catheters during the postoperative intensive care unit stay. The low complication rate from brachial arterial cannulation may be due to high-dose heparin during CPB, and from experience in routine placement for a large number of cases.3Bazaral M.G. Welch M. Golding L.A. Badhwar K. Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery.Anesthesiology. 1990; 73: 38-45Crossref PubMed Scopus (61) Google Scholar In the rare event of complications, they must be rapidly identified and intervened upon to minimize the risks from limb ischemia. The authors did a great job recognizing the issue of radial-to-femoral pressure gradient and alluded to the size of the radial artery as a potential contributor; however, they do not discuss the implications of their research on the current wide spread practice of using radial artery monitoring during cardiac surgery. Because the pressure gradient is so common, even in simple procedures patients may receive unnecessary higher doses of vasopressors, in which case I expect their conclusion to be that an alternative monitoring site should be routinely used. Ultimately, the debate of arterial blood pressure monitoring during cardiac surgery remains open and the conclusion that the sole use of radial arterial pressure monitoring is associated with higher rate of vasopressor use will undoubtedly lead to more questions on the most appropriate cannulation site. Accurate and reliable pressure monitoring is vital for patient care and safety during the perioperative period and brachial arterial catheters have repeatedly been shown to have a significantly greater accuracy and decreased vasopressor use compared with radial catheters.2Scheer B. Perel A. Pfeiffer U. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.Crit Care. 2002; 6: 199Crossref PubMed Google Scholar, 3Bazaral M.G. Welch M. Golding L.A. Badhwar K. Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery.Anesthesiology. 1990; 73: 38-45Crossref PubMed Scopus (61) Google Scholar, 4Singh A. Bahadorani B. Wakefield B. Makarova N. Kumar P.A. Tong M.Z. et al.Brachial arterial pressure monitoring during cardiac surgery rarely causes complications.Anesthesiology. 2017; 126: 1065-1076Crossref PubMed Scopus (13) Google Scholar, 5Armstrong M.K. Schultz M.G. Picone D.S. Black J.A. Dwyer N. Roberts-Thomson P. et al.Brachial and radial systolic blood pressure are not the same.Hypertension. 2019; 73: 1036-1041Crossref PubMed Scopus (25) Google Scholar Compared with femoral arterial catheters, brachial catheters are associated with lower infection risk, as well.2Scheer B. Perel A. Pfeiffer U. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.Crit Care. 2002; 6: 199Crossref PubMed Google Scholar,6Handlogten K. Wilson G. Clifford L. Nuttall G. Kor D. Brachial artery catheterization.Anesth Analg. 2014; 118: 288-295Crossref PubMed Scopus (21) Google Scholar,7Lorente L. Jiménez A. Martín M.M. Jiménez J.J. Iribarren J.L. Mora M.L. Lower arterial catheter-related infection in brachial than in femoral access.Am J Infect Control. 2010; 38: e40-e42Abstract Full Text Full Text PDF PubMed Scopus (6) Google Scholar We make a case based on experience and data from a large cohort of patients that brachial arterial cannulation for blood pressure monitoring during cardiac surgery is a safe and efficient technique for both simple and complex procedures that warrants consideration when dual arterial cannulation would otherwise be required. Radial-to-femoral pressure gradient quantification in cardiac surgeryJTCVS OpenVol. 8PreviewA radial-to-femoral pressure gradient (RFPG) can occur in roughly one-third of cardiac surgical patients. Such a gradient has been associated with smaller stature and potentially smaller radial artery diameter. We hypothesized that preoperative radial artery diameter could be a predictor of RFPG. We also investigated the clinical impact of using a femoral versus a radial arterial catheter in terms of vasoactive support. Full-Text PDF Open Access
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".