Bibliographic record
Abstract
Harmonics are increasingly becoming a major source of power quality problems in today's commercial power distribution systems. Although they have been present in power distribution systems since the early days of AC power systems, their level has dramatically increased and the effect on power distributions has been more and more noticeable in the last decade. This dramatic increase of harmonic levels is mainly due to the introduction of non linear loads such as personal computers, servers, variable frequency drives and UPS systems. Harmonic problems are especially common in commercial buildings housing large computer rooms where the concentration of nonlinear loads per square foot is very high, and continue to grow higher as the footprint of network and communication equipment becomes smaller. This report will provide a deep look at harmonics in power distribution systems in commercial buildings, their sources and the different ways by which they can affect electrical systems and power quality. Some of the solutions commonly used to deal with the problem of harmonics are reviewed, and a critical analysis of their effectiveness is provided. Computer simulations using Matlab Simulink have been developed to illustrate key points when possible.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.006 | 0.002 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".