MétaCan
Menu
Back to cohort
Record W3199015636 · doi:10.21203/rs.3.rs-877642/v1

Study of Silicon Nitride Waveguide Platform for On-Chip Virus Detection: Prospects for COVID-19

2021· preprint· en· W3199015636 on OpenAlexaff
Raghi S. El Shamy, Mohamed A. Swillam, Xun Li

Bibliographic record

VenueResearch Square · 2021
Typepreprint
Languageen
FieldEngineering
TopicPhotonic and Optical Devices
Canadian institutionsMcMaster University
Fundersnot available
KeywordsWaveguideMaterials scienceSilicon nitrideFigure of meritOptoelectronicsInterferometryWavelengthMach–Zehnder interferometerOpticsSensitivity (control systems)Refractive indexPhotonicsSiliconElectronic engineeringPhysics

Abstract

fetched live from OpenAlex

Abstract This work presents a rigorous sensitivity analysis of silicon nitride on silicon dioxide strip waveguide for virus detection, focusing on COVID-19. In general, by functionalizing the waveguide surface with specific antibodies layer, we make the optical sensor sensitive only to a particular virus. Unlike conventional virus detection methods such as polymerase chain reaction (PCR), integrated refractive index (RI) optical sensors offer cheap and mass-scale fabrication of compact devices for fast and straightforward detection with high sensitivity and selectivity. Our analysis includes a wide range of wavelengths from visible to mid-infrared. We determined the strip waveguide's single-mode dimensions and the optimum dimensions that maximize the sensitivity to the virus layer attached to its surface at each wavelength. We also compared the strip waveguide to the widely used slot waveguide. Our study shows that silicon nitride strip waveguide working at lower wavelengths is the optimum choice for virus detection as it maximizes both the waveguide sensitivity (Swg) and the figure of merit (FOM) of the sensor. Furthermore, the optimized waveguide can work for a range of viruses. Balanced Mach-Zehnder interferometer (MZI) sensors were designed at different wavelengths showing high FOM at λ = 450nm ranging from 500 RIU-1 up to 1231 RIU-1 with LMZI=500 µm. Different MZI configurations were also studied and compared. Finally, edge coupling from the fiber to the sensor was designed, showing insertion loss (IL) at λ = 450nm of 4.1 dB for the design with FOM = 500 RIU-1. The obtained coupling efficiencies are higher than recently proposed fiber couplers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.115
GPT teacher head0.399
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueResearch SquareSame topicPhotonic and Optical DevicesFrench-language works237,207