MétaCan
Menu
Back to cohort
Record W3200309890 · doi:10.1159/000517454

Stroke in Patients with Left Ventricular Assist Devices

2021· review· en· W3200309890 on OpenAlexaff
Alyson Plecash, Danielle Byrne, Alana M. Flexman, Mustafa Toma, Thalia S. Field

Bibliographic record

VenueCerebrovascular Diseases · 2021
Typereview
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsVancouver Coastal HealthUniversity of British Columbia
Fundersnot available
KeywordsMedicineDestination therapyStroke (engine)CardiologyVentricular assist devicePopulationInternal medicinePerioperativeHeart failureContext (archaeology)AntithromboticFibrinolytic agentSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Left ventricular assist devices (LVADs) are artificial pumps used in end-stage heart failure to support the circulatory system. These cardiac assist devices work in parallel to the heart, diverting blood from the left ventricle through an outflow graft and into the ascending aorta. LVADs have allowed patients with end-stage heart failure to live longer and with improved quality of life compared to best medical therapy alone. However, they are associated with significant risks related to both thrombosis and bleeding in this medically complex patient population. As LVADs continue to be used more widely, stroke neurologists need to become familiar with the unique physical exam and vascular imaging findings associated with this population. SUMMARY: Reported rates of LVAD-associated stroke at 2 years post-implantation range from 10 to 30%, which is significantly higher than in age-matched controls. There are approximately equal rates of ischemic and hemorrhagic strokes, and rates are highest during the peri-implantation period and in the first year of therapy. Risk factors associated with ischemic and hemorrhagic stroke in this cohort can be grouped into treatment-related factors, including specific devices and antithrombotic/anticoagulation strategy, and patient-related factors. Evidence for reperfusion therapy for acute stroke in this population is limited. Intravenous tissue plasminogen activator (IV-tPA) is often contraindicated as events may occur in the perioperative setting, or in the context of therapeutic anticoagulation. Endovascular therapy with successful recanalization is reported, but there is little experience documented in the published literature. Key messages: LVAD use is increasingly common. Given the high associated risks of stroke, neurologists will need to become increasingly familiar with an approach to assessment and therapy for LVAD patients with cerebrovascular issues.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: none
Teacher disagreement score0.007
Threshold uncertainty score0.025

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0070.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.224
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueCerebrovascular DiseasesSame topicMechanical Circulatory Support DevicesFrench-language works237,207