MétaCan
Menu
Back to cohort
Record W3204083313 · doi:10.1016/j.xjon.2021.09.027

Commentary: Femoral arterial catheters for cardiac surgery: To do it or not to do it? That is the question

2021· editorial· en· W3204083313 on OpenAlexaboutno aff
Alex M. Wisniewski, J. Hunter Mehaffey

Bibliographic record

VenueJTCVS Open · 2021
Typeeditorial
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsnot available
Fundersnot available
KeywordsRadial arteryCardiopulmonary bypassFemoral arteryMedicineAnesthesiologyBlood pressureCardiac surgeryHemodynamicsMean arterial pressureCardiologyArteryAnesthesiaInternal medicineHeart rate

Abstract

fetched live from OpenAlex

Central MessageRFPG is a common with radial artery diameters <1.8 mm and may be predictive of this phenomenon in which femoral artery pressure monitoring is warranted.See Article page 446. RFPG is a common with radial artery diameters <1.8 mm and may be predictive of this phenomenon in which femoral artery pressure monitoring is warranted. See Article page 446. Among many other data points, proper hemodynamic monitoring during cardiopulmonary bypass is crucial because surgeons, anesthesiologists, and perfusionists rely on this data to make informed decisions on intraoperative patient management. Radial-to-femoral pressure gradient (RFPG) is defined as ≥25 mm Hg systolic or ≥10 mm Hg mean arterial pressure difference in radial and femoral pressures for a minimum of 5 consecutive minutes.1Stern D.H. Gerson J.I. Allen F.B. Parker F.B. Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass?.Anesthesiology. 1985; 62: 557-561Crossref PubMed Scopus (99) Google Scholar It occurs in at least one-third to one-half of patients during cardiopulmonary bypass and may persist into the postoperative period.2Bouchard-Dechene V. Couture P. Su A. Deschamps A. Lamarche Y. Desjardins G. et al.Risk factors for radial-to-femoral artery pressure gradient in patients undergoing cardiac surgery with cardiopulmonary bypass.J Cardiothorac Vasc Anesth. 2018; 32: 692-698Abstract Full Text Full Text PDF PubMed Scopus (11) Google Scholar,3Fuda G. Denault A. Deschamps A. Bouchard D. Fortier A. Lambert J. et al.Risk factors involved in central-to-radial arterial pressure gradient during cardiac surgery.Anesth Analg. 2016; 122: 624-632Crossref PubMed Scopus (27) Google Scholar This discrepancy may lead to excessive and inappropriate vasoactive medication use during the perioperative timeframe. The mechanism of RFPG remains unclear, although certain risk factors such as short stature, complexity of operation, and prolonged aortic crossclamp time may play a role in identifying patients at risk for developing RFPG in whom a femoral arterial catheter should be placed.2Bouchard-Dechene V. Couture P. Su A. Deschamps A. Lamarche Y. Desjardins G. et al.Risk factors for radial-to-femoral artery pressure gradient in patients undergoing cardiac surgery with cardiopulmonary bypass.J Cardiothorac Vasc Anesth. 2018; 32: 692-698Abstract Full Text Full Text PDF PubMed Scopus (11) Google Scholar In the present study, the authors suggest smaller radial artery diameter as an additional data point to consider when determining sites of arterial pressure monitoring preoperatively.4Bouchard-Dechêne V. Kontar L. Couture P. Pérusse P. Levesque S. Lamarche Y. et al.Montreal Heart Institute Research TeamRadial-to-femoral pressure gradient quantification in cardiac surgery.J Thorac Cardiovasc Surg Open. 2021; 8: 446-460Google Scholar Bouchard-Dechêne and colleagues4Bouchard-Dechêne V. Kontar L. Couture P. Pérusse P. Levesque S. Lamarche Y. et al.Montreal Heart Institute Research TeamRadial-to-femoral pressure gradient quantification in cardiac surgery.J Thorac Cardiovasc Surg Open. 2021; 8: 446-460Google Scholar describe their prospective experience with RFPG and the role of radial artery diameter in identifying patients at greatest risk for developing this incongruity. The mechanism behind RFPG remains unclear, although vasomotor activity in muscular arteries as a response to catecholamines has been proposed. With smaller radial arteries, this vasoconstriction may lead to a diminished pulse pressure and a subsequent RFPG. The authors looked to prospectively quantify radial artery diameters in patients undergoing cardiac surgery. They demonstrate patients with a smaller radial artery diameter (<1.8 mm) were more likely to experience RFPG than those with larger diameters (>2.2 mm). Patients with a smaller radial artery diameter were also more likely be women, have a lower body weight, lower body mass index, and smaller body surface area. Radial artery diameter may indeed increase the risk of RFPG, although it likely serves as a proxy for known risk factors such as short stature. When comparing single radial arterial monitoring to both radial and femoral arterial monitoring, those with single radial arterial monitoring, despite undergoing isolated procedures with shorter crossclamp and bypass times, received significantly more phenylephrine. In this study, the decision of which arterial lines were placed was at the discretion of the anesthesiologist. The authors state an institutional bias toward dual site monitoring in more complex procedures; this was confirmed by the higher rate of isolated procedures in the single radial catheter cohort. It is likely that those patients receiving more vasoactive medications in the single radial catheter group would have possessed a discrepancy between peripheral and central arterial pressures. Hence, utilization of a femoral arterial catheter may have alleviated this inappropriate phenylephrine use. Perhaps complexity of procedure taken alone is likely not a good predictor of RFPG unless used in addition to other risk factors. Thus, with such a high rate of RFPG in patients undergoing cardiac surgery and the subsequent clinical consequences of excessive vasoactive medication use, should all patients have femoral arterial monitoring? Arterial lines do pose a small risk of bloodstream infection, which is increased with utilization of a femoral line.5O'Horo J.C. Maki D.G. Krupp A.E. Safdar N. Arterial catheters as a source of bloodstream infection: a systematic review and meta-analysis.Crit Care Med. 2014; 42: 1334-1339Crossref PubMed Scopus (76) Google Scholar However, the overall rate of infection remains low, and these lines are typically removed early in the postoperative course. Specifically, femoral lines have risk of retroperitoneal hematoma, although use of small, 4F catheters placed under ultrasound guidance likely mitigates this. Another concern with routine use of femoral arterial lines is the disruption of patient mobility postoperatively. The authors state no issue with this because all their patients are mobilized regardless of presence of a femoral catheter. Other studies have demonstrated that it is indeed safe to ambulate patients with femoral arterial lines and it therefore should not be a barrier to early mobility.6Perme C. Nalty T. Winkelman C. Kenji Nawa R. Masud F. Safety and efficacy of mobility interventions in patients with femoral catheters in the ICU: a prospective observational study.Cardiopulm Phys Ther J. 2013; 24: 12-17Crossref PubMed Google Scholar,7Damluji A. Zanni J.M. Mantheiy E. Colantuoni E. Kho M.E. Needham D.M. Safety and feasibility of femoral catheters during physical rehabilitation in the intensive care unit.J Crit Care. 2013; 28 (535.e9-535.e15)Crossref PubMed Scopus (43) Google Scholar The authors have confirmed known risk factors for RFPG with the addition of radial artery diameter as another tool in the toolbox for raising your suspicion of this intraoperative falsity. RFPG is a common occurrence and may result in inappropriate vasoactive medication use, although whether or not this translates to differences in patient outcomes is unknown from the present study. Femoral arterial catheter use is simple and effective in preventing this complication and should aid in reduction of erroneous vasoactive medication use. For patients with a combination of known risk factors for RFPG such as characteristics of short stature and radial artery diameters <1.8 mm, placement of a femoral arterial catheter should be considered. Radial-to-femoral pressure gradient quantification in cardiac surgeryJTCVS OpenVol. 8PreviewA radial-to-femoral pressure gradient (RFPG) can occur in roughly one-third of cardiac surgical patients. Such a gradient has been associated with smaller stature and potentially smaller radial artery diameter. We hypothesized that preoperative radial artery diameter could be a predictor of RFPG. We also investigated the clinical impact of using a femoral versus a radial arterial catheter in terms of vasoactive support. Full-Text PDF Open Access

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Editorial · Consensus signal: Editorial
Teacher disagreement score0.083
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.382
Teacher spread0.336 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEditorial

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJTCVS OpenSame topicHemodynamic Monitoring and TherapyFrench-language works237,207