MétaCan
Menu
Back to cohort
Record W3206342866 · doi:10.1093/jcag/gwab038

Canadian Association of Gastroenterology (CAG) Position Statement on the Use of Hyoscine-<i>n</i>-butylbromide (Buscopan) During Gastrointestinal Endoscopy

2021· article· en· W3206342866 on OpenAlexaffabout
Nauzer Forbes, Levi Frehlich, Mark Borgaonkar, Grigorios I. Leontiadis, Frances Tse

Bibliographic record

VenueJournal of the Canadian Association of Gastroenterology · 2021
Typearticle
Languageen
FieldMedicine
TopicColorectal Cancer Screening and Detection
Canadian institutionsMcMaster UniversityPopulation Health Research InstituteMemorial University of NewfoundlandUniversity of Calgary
Fundersnot available
KeywordsMedicineColonoscopyEndoscopic submucosal dissectionEndoscopyGrading (engineering)Internal medicineGeneral surgerySurgery

Abstract

fetched live from OpenAlex

Abstract Hyoscine butylbromide, also known as hyoscyamine or scopolamine, and sold under the trade name Buscopan, is an antimuscarinic agent commonly used to induce smooth muscle relaxation and reduce spasmodic activity of the gastrointestinal (GI) tract during endoscopic procedures. However, the balance between desirable and undesirable (adverse) effects is not clear when used during GI endoscopy. The Clinical Affairs Committee of the Canadian Association of Gastroenterology (CAG) conducted systematic reviews and applied the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach to develop recommendations for the use of Buscopan during GI endoscopy. To summarize, we recommend against the use of Buscopan before or during colonoscopy (strong recommendation, high certainty of evidence). We suggest against the use of Buscopan before or during gastroscopy (conditional recommendation, very low certainty of evidence). We suggest the use of Buscopan before or during ERCP (conditional recommendation, very low certainty of evidence). More research is needed to determine whether patients undergoing advanced procedures such as endoscopic mucosal resection or endoscopic submucosal dissection benefit from its use. Buscopan should be used with caution in patients with cardiac comorbidities. According to its product monograph, Buscopan is contraindicated in patients with tachycardia, angina, and cardiac failure. Thus, Buscopan should be used very cautiously in patients with these conditions, and only when the potential benefits of its use outweigh the potential risks in a particular case. Such patients require careful cardiac monitoring in an environment where resuscitation equipment and appropriately trained staff to use it are readily available. According to its product monograph, Buscopan is also contraindicated in patients with prostatic hypertrophy with urinary retention, and therefore, should be used very cautiously in such patients as well, and only when the potential benefits of its use outweigh the potential risks in a particular case. Obtaining a preprocedural history of glaucoma is unlikely to be of value when considering Buscopan use. However, in cases where Buscopan has been used, patients should be counselled postprocedurally and told to present to an emergency facility should they experience eye pain, redness, decreased vision, nausea and vomiting or headache.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.030
metaresearch head score (Gemma)0.113
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Editorial · Consensus signal: none
Teacher disagreement score0.246
Threshold uncertainty score0.489

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0300.113
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.005
Bibliometrics0.0060.005
Science and technology studies0.0030.003
Scholarly communication0.0050.002
Open science0.0050.002
Research integrity0.0140.010
Insufficient payload (model declined to judge)0.0130.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.234
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEditorial

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueJournal of the Canadian Association of GastroenterologySame topicColorectal Cancer Screening and DetectionFrench-language works237,207