MétaCan
Menu
Back to cohort
Record W3206987408 · doi:10.5489/cuaj.7362

Clinical validation of an audio-based uroflowmetry app in adult males

2021· article· en· W3206987408 on OpenAlexaffvenue
Mark Dawidek, Rohit Singla, Lucie Spooner, Louisa Ho, Christopher Nguan

Bibliographic record

VenueCanadian Urological Association Journal · 2021
Typearticle
Languageen
FieldMedicine
TopicPhonocardiography and Auscultation Techniques
Canadian institutionsUniversity of British Columbia
FundersPfizer
KeywordsRepeatabilityCorrelationCorrelation coefficientMedicineGold standard (test)Intraclass correlationPearson product-moment correlation coefficientLimits of agreementLower urinary tract symptomsAudiologyPhysical therapyMathematicsStatisticsReproducibilityNuclear medicineRadiologyInternal medicine

Abstract

fetched live from OpenAlex

INTRODUCTION: Uroflowmetry is a common test to evaluate lower urinary tract symptoms. Audio-based uroflowmetry is a novel, alternative approach that determines urine flow by measuring sound. Available as a smartphone application, it has potential for screening and monitoring common urological pathologies, particularly in out-of-office environments. This study is the first to evaluate audio-based uroflowmetry in a clinical setting against the gold standard. METHODS: Adult male patients (n=44) attending a general urology clinic were recruited. Audio-based uroflowmetry and conventional uroflowmetry were performed concurrently. Pearson correlation and Bland-Altman analysis were used to compare performance with respect to max flow, time to max flow, and total voiding time. Symmetric mean absolute percentage error (SMAPE) was used to compare curve shapes. Repeatability was evaluated separately in three healthy volunteers using repeat measures correlation. RESULTS: Among urology clinic patients, the correlation for max flow was 0.12. Correlation for time to max flow was 0.46, with limits of agreement of -120-165%. Correlation for total voiding time was 0.91, with limits of agreement of -41-38%. The SMAPE for curve shape was 32.6%, with corresponding accuracy of 67.4%. Among healthy volunteers, the repeat measures correlation for max flow was 0.72. CONCLUSIONS: Audio-based uroflowmetry was inconsistent in evaluating flow rate, attributable to high variability and difficult standardization for acoustic signals. Performance improved with respect to temporal variables, as well as flow curve shape. Further work evaluating intra-patient reliability and pathology-specific performance is required to fully evaluate audio-based uroflowmetry as a screening or monitoring tool.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.034

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.015
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.295
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Urological Association JournalSame topicPhonocardiography and Auscultation TechniquesFrench-language works237,207