MétaCan
Menu
Back to cohort
Record W3207471536 · doi:10.1063/5.0061820

Design, analysis, and experimental investigation of micro-displacement amplification compliant mechanism for micro-transducers

2021· article· en· W3207471536 on OpenAlexaff
Sohail Iqbal, Yongjun Lai, Rana Iqtidar Shakoor, Muhammad Raffi, Shafaat A. Bazaz

Bibliographic record

VenueReview of Scientific Instruments · 2021
Typearticle
Languageen
FieldEngineering
TopicPiezoelectric Actuators and Control
Canadian institutionsQueen's University
FundersHigher Education Commision, Pakistan
KeywordsStructural dynamicsAmplification factorBucklingDisplacement (psychology)Mechanism (biology)Structural engineeringModal analysisParametric statisticsSafety factorNatural frequencyTransducerMaterials scienceAcousticsVibrationPhysicsFinite element methodEngineeringOptoelectronicsMathematics

Abstract

fetched live from OpenAlex

This paper presents experimental force and buckling analysis of a compliant micro-displacement amplification mechanism fabricated using the commercially available PolyMUMPs process. The proposed mechanism proficiently amplifies displacement, at two output ends, with an optimal amplification factor of 7.2. Buckling analysis revealed that an amplification factor ranging from 2.8 to 11 may be achieved for an input displacement varying from 0.1 to 7.5 µm. Based on the analysis, the optimal value of the amplification factor is found to be 7.2 with an input displacement of 3.5 µm at the operational force of 60 μN having a buckling load factor (BLF) >1. Critical load magnitude is 187 μN having BLF = 1. Buckling occurred when loading exceeded the critical load value, having BLF <1, and the mechanism failed to produce a significant amplification factor. Static analysis showed that stresses produced are within the safe region, and the structural integrity of the mechanism is not compromised having a factor of safety of 1.4. Modal analysis predicted that the natural frequency of the desired mode is 35.47 kHz. Dynamic simulations, under 15 g dynamic load with a frequency range of 30–40 kHz, confirm the possibility of integrating the proposed mechanism with MEMS devices. Parametric optimization comprehends that length and angle are the two major geometric parameters that govern the working range, force, and amplification factor. For input displacements below 1 µm, the amplification factor is even higher, which is highly beneficial for amplifying small displacements. Static, modal, and dynamic analyses of the designed mechanism have been carried out using finite element method based commercial software IntelliSuite®. The experimental results showed that this mechanism can provide the same amplified displacement at two output points and is self-sufficient to be incorporated as an intermediate compliant mechanism for enhancing the output in the case of both static and dynamic micro-devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.122
Threshold uncertainty score0.449

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.250
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicPiezoelectric Actuators and ControlFrench-language works237,207