Abstract

fetched live from OpenAlex

Abstract Veterinary workers use lead shielding for protection against harm from ionizing radiation during diagnostic imaging. Surface lead on shielding has been reported as a potential exposure hazard. The purpose of this prospective, analytical, descriptive study was to measure surface lead on lead‐containing shielding in the field service and small animal radiology areas of a veterinary teaching hospital, and to examine potential risk factors for surface lead. Surface lead on a convenience sample of 54 lead shielding items was measured in a commercial laboratory using inductively coupled plasma mass spectrometry. The median and range of surface lead for aprons, thyroid collars, and gloves were 3.6 μg/dm2 (range, 1.3‐22.4 μg/dm2), 23.1 μg/dm2 (range, 2.6‐116 μg/dm2), and 134 μg/dm2 (range, 1.5‐155 μg/dm2), respectively. In the final multivariable analysis, the mean surface lead on thyroid collars and gloves was higher than on aprons (relative differences 4.8, 95% confidence interval [CI] 2.2, 10.5, P < 0.001; and 9.5, 95% CI 4.4, 20.6, P < 0.001, respectively). The mean surface lead on shielding in the worst condition was higher than on shielding in the intermediate and best conditions (P < 0.001). Lead shielding provides effective protection against the harmful effects of ionizing radiation, and shielding should always be worn during radiation exposure. Based on our findings and the common use of lead shielding in veterinary workplaces, we recommend that employers inform workers of this hazard and provide training on steps to mitigate exposure, including the use of disposable gloves when wearing lead shielding and handwashing after use.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Commentary · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.026

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0020.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0080.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.082
GPT teacher head0.326
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreCommentary

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueVeterinary Radiology & UltrasoundSame topicRadiation Dose and ImagingFrench-language works237,207