Thoracoscopic surgical ablation versus catheter ablation as first-line treatment for long-standing persistent atrial fibrillation: the CASA-AF RCT
Bibliographic record
Abstract
Background Standalone thoracoscopic surgical ablation may be more effective than catheter ablation in patients with long-standing persistent atrial fibrillation. Objectives To determine whether or not surgical ablation is clinically superior to catheter ablation as the first-line treatment strategy in long-standing persistent atrial fibrillation. Design This was a prospective, multicentre, randomised control trial. Setting Four NHS tertiary centres in England. Participants Adults with long-standing persistent atrial fibrillation, who had European Heart Rhythm Association symptom scores > 2 and who were naive to previous catheter ablation or thoracic/cardiac surgery. Interventions Minimally invasive thoracoscopic surgical ablation and conventional catheter ablation (control intervention). Main outcome measures The primary outcome was freedom from atrial fibrillation/tachycardia ≥ 30 seconds after a single procedure without antiarrhythmic drugs (class 1C/3) at 1 year, excluding a 3-month blanking period. The secondary outcomes include the intervention-related major complication rate; clinical success (≥ 75% reduction in arrhythmia burden); and changes in symptoms, quality of life and cost-effectiveness. Methods Patients (n = 120) were randomised to surgical ablation (n = 60) or catheter ablation (n = 60). An implanted loop recorder provided continuous cardiac monitoring following ablation. Follow-up visits were at 3, 6, 9 and 12 months. Loop recorder data were reviewed monthly by a physiologist who was blinded to the randomisation outcome. Results The study treatment was received by 55 patients in the surgical ablation arm and 60 patients in the catheter ablation arm; five patients withdrew from surgical ablation before treatment. Data from randomised and treated patients were analysed as per intention to treat. Patients had a mean age of 62.3 (standard deviation 9.6) years, were predominantly male (74%), had a mean left atrial diameter of 44.6 mm (standard deviation 6 mm) and were in continuous atrial fibrillation for 22 months (range 16–31 months). At 12 months, 26% of patients in the surgical ablation arm (14/54) and 28% of patients in the catheter ablation arm (17/60) were free from atrial arrhythmias after a single procedure without antiarrhythmic drugs (odds ratio 1.13, 95% confidence interval 0.46 to 2.83; p = 0.84). An arrhythmia burden reduction of ≥ 75% was seen in 36 out of 54 (67%) patients in the surgical ablation arm, compared with 46 out of 60 (77%) patients in the catheter ablation arm (odds ratio 1.64, 95% confidence interval 0.67 to 4.08; p = 0.3). Procedure-related serious complications within 30 days of the intervention occurred in 15% (8/55) of patients in the surgical ablation arm (including one death) compared with 10% (6/60) of patients in the catheter ablation arm (p = 0.46). Surgical ablation was associated with significantly higher costs (£23,221 vs. £18,186; p = 0.02) and fewer quality-adjusted life-years than catheter ablation (0.76 vs. 0.83; p = 0.02). Limitations This study was conducted in four highly specialised cardiology centres that have substantial experience in both treatment modalities; therefore, the results may not be widely generalisable. The study was not powered to detect small differences in efficacy. Conclusions We found no evidence to suggest that standalone thoracoscopic surgical ablation outcomes were superior to catheter ablation outcomes in achieving freedom from atrial arrhythmia after a single procedure without antiarrhythmic drugs. Moreover, surgical ablation is associated with a longer hospital stay, smaller improvements in quality of life and higher health-care costs than catheter ablation (standard care therapy). Future work Evaluation of the impact of ablation treatments on sinus rhythm maintenance and quality of life with extended follow-up to 3 years. Model-based economic analysis to estimate long-term benefits, harms and costs of surgical and catheter ablation compared with antiarrhythmic drug therapy in long-standing persistent atrial fibrillation patients. Trial registration Current Controlled Trials ISRCTN18250790 and ClinicalTrials.gov NCT02755688. Funding This project was funded by the Efficacy and Mechanism Evaluation (EME) programme, a Medical Research Council (MRC) and National Institute for Health Research (NIHR) partnership. This study was supported by the UK Clinical Research Collaboration-registered King’s Clinical Trials Unit at King’s Health Partners, which is part funded by the NIHR Biomedical Research Centre for Mental Health at South London and Maudsley NHS Foundation Trust and King’s College London and the NIHR Evaluation, Trials and Studies Coordinating Centre. This will be published in full in Efficacy and Mechanism Evaluation; Vol. 8, No. 18. See the NIHR Journals Library website for further project information.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.004 | 0.008 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.004 | 0.004 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.002 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.003 | 0.002 |
| Insufficient payload (model declined to judge) | 0.008 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".