MétaCan
Menu
Back to cohort
Record W3208342961 · doi:10.3310/eme08180

Thoracoscopic surgical ablation versus catheter ablation as first-line treatment for long-standing persistent atrial fibrillation: the CASA-AF RCT

2021· article· en· W3208342961 on OpenAlexaff
Shouvik Haldar, Habib Khan, Vennela Boyalla, Ines Kralj‐Hans, Simon Jones, Joanne Lord, Olu Onyimadu, Anitha Sathishkumar, Toufan Bahrami, Jonathan R. Clague, Anthony De Souza, Dárrel P. Francis, Wajid Hussain, Julian W.E. Jarman, David G. Jones, Zhong Chen, Neeraj Mediratta, Jonathan Hyde, Michael E. Lewis, Raad Mohiaddin, Tushar V. Salukhe, Caroline Murphy, Joanna Kelly, Rajdeep Khattar, William D. Toff, Vias Markides, James McCready, Dhiraj Gupta, Tom Wong

Bibliographic record

VenueEfficacy and Mechanism Evaluation · 2021
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsLondon Health Sciences CentreWestern University
FundersEfficacy and Mechanism Evaluation ProgrammeMedical Research Council
KeywordsMedicineAtrial fibrillationAblationCatheter ablationRandomized controlled trialSurgeryCatheterAtrial tachycardiaCardiologyInternal medicine

Abstract

fetched live from OpenAlex

Background Standalone thoracoscopic surgical ablation may be more effective than catheter ablation in patients with long-standing persistent atrial fibrillation. Objectives To determine whether or not surgical ablation is clinically superior to catheter ablation as the first-line treatment strategy in long-standing persistent atrial fibrillation. Design This was a prospective, multicentre, randomised control trial. Setting Four NHS tertiary centres in England. Participants Adults with long-standing persistent atrial fibrillation, who had European Heart Rhythm Association symptom scores > 2 and who were naive to previous catheter ablation or thoracic/cardiac surgery. Interventions Minimally invasive thoracoscopic surgical ablation and conventional catheter ablation (control intervention). Main outcome measures The primary outcome was freedom from atrial fibrillation/tachycardia ≥ 30 seconds after a single procedure without antiarrhythmic drugs (class 1C/3) at 1 year, excluding a 3-month blanking period. The secondary outcomes include the intervention-related major complication rate; clinical success (≥ 75% reduction in arrhythmia burden); and changes in symptoms, quality of life and cost-effectiveness. Methods Patients (n = 120) were randomised to surgical ablation (n = 60) or catheter ablation (n = 60). An implanted loop recorder provided continuous cardiac monitoring following ablation. Follow-up visits were at 3, 6, 9 and 12 months. Loop recorder data were reviewed monthly by a physiologist who was blinded to the randomisation outcome. Results The study treatment was received by 55 patients in the surgical ablation arm and 60 patients in the catheter ablation arm; five patients withdrew from surgical ablation before treatment. Data from randomised and treated patients were analysed as per intention to treat. Patients had a mean age of 62.3 (standard deviation 9.6) years, were predominantly male (74%), had a mean left atrial diameter of 44.6 mm (standard deviation 6 mm) and were in continuous atrial fibrillation for 22 months (range 16–31 months). At 12 months, 26% of patients in the surgical ablation arm (14/54) and 28% of patients in the catheter ablation arm (17/60) were free from atrial arrhythmias after a single procedure without antiarrhythmic drugs (odds ratio 1.13, 95% confidence interval 0.46 to 2.83; p = 0.84). An arrhythmia burden reduction of ≥ 75% was seen in 36 out of 54 (67%) patients in the surgical ablation arm, compared with 46 out of 60 (77%) patients in the catheter ablation arm (odds ratio 1.64, 95% confidence interval 0.67 to 4.08; p = 0.3). Procedure-related serious complications within 30 days of the intervention occurred in 15% (8/55) of patients in the surgical ablation arm (including one death) compared with 10% (6/60) of patients in the catheter ablation arm (p = 0.46). Surgical ablation was associated with significantly higher costs (£23,221 vs. £18,186; p = 0.02) and fewer quality-adjusted life-years than catheter ablation (0.76 vs. 0.83; p = 0.02). Limitations This study was conducted in four highly specialised cardiology centres that have substantial experience in both treatment modalities; therefore, the results may not be widely generalisable. The study was not powered to detect small differences in efficacy. Conclusions We found no evidence to suggest that standalone thoracoscopic surgical ablation outcomes were superior to catheter ablation outcomes in achieving freedom from atrial arrhythmia after a single procedure without antiarrhythmic drugs. Moreover, surgical ablation is associated with a longer hospital stay, smaller improvements in quality of life and higher health-care costs than catheter ablation (standard care therapy). Future work Evaluation of the impact of ablation treatments on sinus rhythm maintenance and quality of life with extended follow-up to 3 years. Model-based economic analysis to estimate long-term benefits, harms and costs of surgical and catheter ablation compared with antiarrhythmic drug therapy in long-standing persistent atrial fibrillation patients. Trial registration Current Controlled Trials ISRCTN18250790 and ClinicalTrials.gov NCT02755688. Funding This project was funded by the Efficacy and Mechanism Evaluation (EME) programme, a Medical Research Council (MRC) and National Institute for Health Research (NIHR) partnership. This study was supported by the UK Clinical Research Collaboration-registered King’s Clinical Trials Unit at King’s Health Partners, which is part funded by the NIHR Biomedical Research Centre for Mental Health at South London and Maudsley NHS Foundation Trust and King’s College London and the NIHR Evaluation, Trials and Studies Coordinating Centre. This will be published in full in Efficacy and Mechanism Evaluation; Vol. 8, No. 18. See the NIHR Journals Library website for further project information.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.026

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.008
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.004
Bibliometrics0.0000.001
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0080.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.174
GPT teacher head0.408
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueEfficacy and Mechanism EvaluationSame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207